FBD 77 FC Series Installation & Operation Manual Download Page 7

7

INSTALLATION & OPERATION ADDENDUM

77X SERIES–FC

DIAGRAMS AND SCHEMATICS

Flow Diagram (FC Low Temperature Dispenser)

L

E

G

E

N

D

VALVE

VARIABLE

RESTRICTION

CHECK

VALVE

P

PRESSURE

TRANSDUCER

S

SOLENOID

VALVE

PRESSURE

REGULATOR

Pressure 

Regulator

CO2 

Supply

Inline 

Pressure 

Transducer

Inline 

Pressure 

Transducer

BRL 1 

Product 

Source

Inline 

Pressure 

Transducer

Gas Block

S

S

Expansion 

Tank

Product 

Barrel

BRL 2 

Product 

Source

Inline 

Pressure 

Transducer

Gas Block

Expansion 

Tank

Product 

Barrel

BRL 3 

Product 

Source

Inline 

Pressure 

Transducer

Expansion 

Tank

Product 

Barrel

BRL 4 

Product 

Source

Inline 

Pressure 

Transducer

Expansion 

Tank

Product 

Barrel

Liquid Flow

Gas Flow

Check 

Valve

Check 

Valve

Solenoid

S

Gas 

Solenoid

Check 

Valve

Gas 

Solenoid

Check 

Valve

Pressure 

Transducer

Pressure 

Transducer

Optional 2, 3, or 4 Barrel Configurations

Shutoff

Valve

Flow Module

S

Flow Module

S

Flow Module

S

Flow Module

Gas Module

Gas Block

Check 

Valve

S

Gas 

Solenoid

Check 

Valve

Pressure 

Transducer

Gas Module

Gas Block

Check 

Valve

S

Gas 

Solenoid

Check 

Valve

Pressure 

Transducer

Gas Module

Gas Module

Dispense 

Valve

Dispense 

Valve

Dispense 

Valve

Solenoid

Shutoff

Valve

Solenoid

Shutoff

Valve

Solenoid

Shutoff

Valve

Dispense 

Valve

Summary of Contents for 77 FC Series

Page 1: ...77X SERIES INSTALLATION OPERATION ADDENDUM FOR LOW TEMPERATURE FROZEN COCKTAIL 24 77XA 0003_03...

Page 2: ...ardless of the theory of liability arising out of or in any manner related to FBD parts equipment or any delay with respect to its delivery The information contained in this document is subject to cha...

Page 3: ...uirements INSTALLATION Dispenser Mounting The FC unit is not designed to be sealed to a countertop surface or floor use the information in this section instead of Section 4 2 in the Installation and O...

Page 4: ...n Manual for details Additionally FC syrup equipment must be rated for use with direct food contact as well as alcohol contact with an ABV of less than 14 LEAK CHECK AND PRIME Leak Check and Prime FC...

Page 5: ...nlikestandardFBDdispensers DisregardtherequirementinSection 8 1 of the Installation and Operation Manual to disconnect the water lines Sanitizing Use the information in the following table instead of...

Page 6: ...as solenoid when the barrel has been emptied 13 Activate the solution solenoid and beater motor again When the barrel is 1 2 full deactivate the solution solenoid to stop the fill process 14 Activate...

Page 7: ...Barrel BRL 4 Product Source Inline Pressure Transducer Expansion Tank Product Barrel Liquid Flow Gas Flow Check Valve Check Valve Solenoid S Gas Solenoid Check Valve Gas Solenoid Check Valve Pressure...

Page 8: ...SS VALVE REFRIGERATION DIAGRAM INSULATION REQUIRED FILTER DRIER TEMPERATURE SENSOR T P PRESSURE SENSOR EXPANSION VALVE 03 03 BARREL EVAPORATOR 02 BARREL EVAPORATOR 01 BARREL EVAPORATOR EXPANSION VALVE...

Page 9: ...l of this product must comply with local regulations Dispenser is not to be disposed of with household waste Contact the retailer where this dispenser was purchased or recycle by locating an authorize...