INSTALLATION & OPERATION ADDENDUM
77X SERIES–FC
4
Supply Connections
The FC low temperature dispenser does not have connections for water. Refer to
Figure 1
below rather than Figure 4.3 in
Section 4.9 of the Installation and Operation Manual.
Connecting to Water Supply
FC low temperature dispensers are not to be connected to any water sources. Section 4.10 in the Installation and Operation
Manual is not applicable to FC units.
Connecting to Syrup Supply
The desired beverage product must be pumped into the machine using suitably certified equipment; please refer to Section
4.12 in the Installation and Operation Manual for details. Additionally, FC syrup equipment must be rated for use with
direct food contact, as well as alcohol contact with an ABV of less than 14%.
LEAK CHECK AND PRIME
Leak Check and Prime
FC dispensers do not have water supply connections unlike standard FBD dispensers. Use the information in the following
table instead of the equivalent table in Section 5.1 of the Installation and Operation Manual.
Table continued on next page.
Figure 1. Bulkhead Fittings for FC Units
1
Remove the side panels by loosening the two screws located at the bottom of the panel and then
lifting off the frame.
2
Remove the drip tray by lifting up and pulling away, then remove the splash plate and access panel
to expose the solution modules.
3
Connect the BIB connectors to the syrup BIBs.