INSTALLATION & OPERATION ADDENDUM

77X SERIES–FC

4

Supply Connections

The FC low temperature dispenser does not have connections for water. Refer to 

Figure 1

 below rather than Figure 4.3 in 

Section 4.9 of the Installation and Operation Manual.

Connecting to Water Supply

FC low temperature dispensers are not to be connected to any water sources. Section 4.10 in the Installation and Operation 

Manual is not applicable to FC units.

 

Connecting to Syrup Supply

The desired beverage product must be pumped into the machine using suitably certified equipment; please refer to Section 

4.12 in the Installation and Operation Manual for details.  Additionally, FC syrup equipment must be rated for use with 

direct food contact, as well as alcohol contact with an ABV of less than 14%.

LEAK CHECK AND PRIME

Leak Check and Prime

FC dispensers do not have water supply connections unlike standard FBD dispensers. Use the information in the following 

table instead of the equivalent table in Section 5.1 of the Installation and Operation Manual. 

Table continued on next page.

Figure 1.  Bulkhead Fittings for FC Units

1

Remove the side panels by loosening the two screws located at the bottom of the panel and then 

lifting off the frame.

2

Remove the drip tray by lifting up and pulling away, then remove the splash plate and access panel 

to expose the solution modules.

3

Connect the BIB connectors to the syrup BIBs.

Summary of Contents for 77 FC Series

Page 1: ...77X SERIES INSTALLATION OPERATION ADDENDUM FOR LOW TEMPERATURE FROZEN COCKTAIL 24 77XA 0003_03...

Page 2: ...ardless of the theory of liability arising out of or in any manner related to FBD parts equipment or any delay with respect to its delivery The information contained in this document is subject to cha...

Page 3: ...uirements INSTALLATION Dispenser Mounting The FC unit is not designed to be sealed to a countertop surface or floor use the information in this section instead of Section 4 2 in the Installation and O...

Page 4: ...n Manual for details Additionally FC syrup equipment must be rated for use with direct food contact as well as alcohol contact with an ABV of less than 14 LEAK CHECK AND PRIME Leak Check and Prime FC...

Page 5: ...nlikestandardFBDdispensers DisregardtherequirementinSection 8 1 of the Installation and Operation Manual to disconnect the water lines Sanitizing Use the information in the following table instead of...

Page 6: ...as solenoid when the barrel has been emptied 13 Activate the solution solenoid and beater motor again When the barrel is 1 2 full deactivate the solution solenoid to stop the fill process 14 Activate...

Page 7: ...Barrel BRL 4 Product Source Inline Pressure Transducer Expansion Tank Product Barrel Liquid Flow Gas Flow Check Valve Check Valve Solenoid S Gas Solenoid Check Valve Gas Solenoid Check Valve Pressure...

Page 8: ...SS VALVE REFRIGERATION DIAGRAM INSULATION REQUIRED FILTER DRIER TEMPERATURE SENSOR T P PRESSURE SENSOR EXPANSION VALVE 03 03 BARREL EVAPORATOR 02 BARREL EVAPORATOR 01 BARREL EVAPORATOR EXPANSION VALVE...

Page 9: ...l of this product must comply with local regulations Dispenser is not to be disposed of with household waste Contact the retailer where this dispenser was purchased or recycle by locating an authorize...

Reviews: