FBD 77 FC Series Installation & Operation Manual Download Page 2

INSTALLATION & OPERATION ADDENDUM

77X SERIES–FC

2

This addendum is for general purposes and is not intended to cover every potential installation or operational possibility.  The parts 

and equipment addressed herein are warranted only to the extent covered by FBD’s Parts and Equipment Warranty.  FBD makes 

no express warranties as to any matter whatsoever and hereby disclaims all implied warranties including, without limitation, the 

implied warranties of merchantability and fitness for any particular purpose.  In no event shall FBD be liable or obligated to any 

customer or to any third party for incidental, consequential, or special damages, regardless of the theory of liability, arising out of, 

or in any manner related to FBD parts, equipment or any delay with respect to its delivery.

The information contained in this document is subject to change without notice.

© 2024 FBD Partnership, L.P. All Rights Reserved.

FBD TECHNICAL SUPPORT: +852 2369 3998 (INTERNATIONAL), or www.fbdfrozen.com

Important Information About this Addendum

This addendum contains installation information specific to low temperature FC dispensers, and serves as a companion to the 

77X Installation & Operation Manual (24-77XM-0012).  This addendum contains additional information intended to supplement 

the 77X Installation & Operation Manual; it does not provide all the information necessary to install or operate the dispenser.  

Familiarize yourself with the manual and this addendum before installing or operating the dispenser. 

Summary of Contents for 77 FC Series

Page 1: ...77X SERIES INSTALLATION OPERATION ADDENDUM FOR LOW TEMPERATURE FROZEN COCKTAIL 24 77XA 0003_03...

Page 2: ...ardless of the theory of liability arising out of or in any manner related to FBD parts equipment or any delay with respect to its delivery The information contained in this document is subject to cha...

Page 3: ...uirements INSTALLATION Dispenser Mounting The FC unit is not designed to be sealed to a countertop surface or floor use the information in this section instead of Section 4 2 in the Installation and O...

Page 4: ...n Manual for details Additionally FC syrup equipment must be rated for use with direct food contact as well as alcohol contact with an ABV of less than 14 LEAK CHECK AND PRIME Leak Check and Prime FC...

Page 5: ...nlikestandardFBDdispensers DisregardtherequirementinSection 8 1 of the Installation and Operation Manual to disconnect the water lines Sanitizing Use the information in the following table instead of...

Page 6: ...as solenoid when the barrel has been emptied 13 Activate the solution solenoid and beater motor again When the barrel is 1 2 full deactivate the solution solenoid to stop the fill process 14 Activate...

Page 7: ...Barrel BRL 4 Product Source Inline Pressure Transducer Expansion Tank Product Barrel Liquid Flow Gas Flow Check Valve Check Valve Solenoid S Gas Solenoid Check Valve Gas Solenoid Check Valve Pressure...

Page 8: ...SS VALVE REFRIGERATION DIAGRAM INSULATION REQUIRED FILTER DRIER TEMPERATURE SENSOR T P PRESSURE SENSOR EXPANSION VALVE 03 03 BARREL EVAPORATOR 02 BARREL EVAPORATOR 01 BARREL EVAPORATOR EXPANSION VALVE...

Page 9: ...l of this product must comply with local regulations Dispenser is not to be disposed of with household waste Contact the retailer where this dispenser was purchased or recycle by locating an authorize...