9
6. STARTING UP THE DISPENSER
6.1 Leak Check
1
Remove the drip tray below the dispenser and remove the front metal panel covered with the drip
tray. The two solution modules inside the dispenser should be visible once metal panel is removed.
2
Connect the BIB connectors to the syrup BIB’s.
3
Open the water supply shutoff valve (
Section 5.5
). On one of the solution modules, close the CO
2
shutoff valve (
Figure 6.1
). Open the sample valve until water flows out of the sample port, then
close the sample valve.
4
Open the CO
2
, water, and syrup shutoff valves.
Note:
The pump and syrup pump will operate automatically and feed the dispenser until the inter-
nal pressure is balanced. This feed is normal and does not last long.
5
Check all connections thoroughly for leaks.
6
Open the sample valve
(Figure 6.1)
and collect the water/syrup being dispensed into a cup.
Continue to prime until syrup flow has been established and all air has been removed from the
lines. Discard the samples.
7
Repeat for the other module.
Sample Port
(hose not shown)
Sample Valve
(shown in open
position)
CO
2
Shutoff Valve
(shown in open
position)
Figure 6.1
Solution Module and Sample Valve Discharge
6.2 Initial Power Up
Plug the dispenser into the power supply and verify the dispenser turns on by looking at the display behind
the merchandiser (see
Section 5.4
). The LCD display should illuminate and should read "COPYRIGHT
94-2019 FBD" on the bottom line. See Section 10 for additional information on keypad buttons and how to
navigate through menus.
Note:
If the screen does not power on, please power off the dispenser immediately and contact the dealer.