PERIODIC MAINTENANCE CHECK 
 
SUCTION UNIT WAS DESIGNED TO KEEP MAINTENANCE TO A MINIMUM. NEVERTHELESS IT IS 
NECESSARY TO CARRY OUT A DAILY CHECK BEFORE USING THE APPLIANCE. 
 
BEFORE CARRYING OUT ANY CHECK DUE TO MALFUNCTIONING OR ANOMALIES, CALL THE FAZZINI 
S.R.L. TECHNICAL SERVICE OR PERSONNEL QUALIFIED BY FAZZINI S.R.L.

  

 

BATTERY CAN BE CHANGED ONLY BY TRAINED PEOPLE 
 
FAZZINI S.R.L. DOES NOT OFFER ANY WARRANTY ON APPLIANCE THAT UPON INSPECTION BY THE 
TECHNICAL SERVICE SHOWS SIGNS OF  TAMPERING. 
 
THE OPERATOR MUST EXCLUSIVELY REPLACE THE SUPPLIED ACCESSORIES IF NECESSARY IN LINE 
WITH THE APPLIANCE’S USE INTENSITY 
 
ASPIRATION TUBES SHOULD BE STERILIZED AFTER EACH USE.  IN CASE OF REPAIR, THE USER 
SHOULD CALL FAZZINI S.R.L. TRANSPORTATION COSTS MUST ALWAYS BE AGREED WITH FAZZINI S.R.L.  
BEFORE SHIPPING FAILED PIECES. 
 
SHOULD ANY FLUID LEAK IN THE APPLIANCE, CALL THE TECHNICAL SERVICE OF FAZZINI S.R.L. FOR 
MAINTENANCE. DO NOT OPEN THE UNIT. 
 
 
STORAGE 
 
THE SUCTION UNIT MUST BE STORED IN A DRY LOCATION, PROTECTED FROM ATMOSPHERIC AGENTS 
STORAGE TEMPERATURE: BETWEEN -10° AND + 55° 
RELATIVE HUMIDITY BETWEEN 20 AND 80%   
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for F-31

Page 1: ...Suction Unit F 31 S e r v i c e M a n u a l Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 1 of 12 NOTE This manual is related to the following Equipment Suction Pump F 31 ...

Page 2: ...SING THE APPLIANCE UNDER DIFFERENT CONDITIONS THAN THOSE SPECIFIED IN THIS HANDBOOK MAY PREJUDICE ITS SAFETY AND ITS TECHNICAL PARAMETERS DELIVERY AND UNCRATING OF UNIT Inspect equipment and shipping crate immediately upon receipt If any damage is apparent you should both report it to the trucking delivery person and contact the transportation company immediately Make notes of any damage on the Bi...

Page 3: ...WER SUPPLY 12V or 110 230V 50 60 Hz MAX VACUUM bar 0 70 MAX FLOW WITH FILTER l mins 10 MAX FLOW DIRECT MEASUREMENT ON ASPIRATION VENT l mins 18 BATTERY code 05 0040 12V 3 3AH FUSES A 2x1 25 ACCESSORIES INCLUDED CODE N DESCRIPTION 05 0001 OR 05 0002 JAR 1000 ML OR 2000 ML 05 00552 SET OF TUBES 05 0010 ASPIRATION PROBE CH 14 DISPOSABLE 05 0016 ANTIBACTERIAL HYDROPHOBIC FILTER DISPOSABLE ...

Page 4: ... is completely flat and is not immediately recharged after use must be replaced by the authorized technical assistance When recharging always make sure the warning light on the front panel is on 1 WHEN ON THE DEVICE S DISPLAY ONLY THE RED LED IS ON WHILE THE GREEN LED AND THE TWO YELLOW LED ARE OFF IT IS NECESSARY TO DISCONTINUE OPERATIONS AND RECHARGE THE DEVICE 2 TO CHARGE THE DEVICE KEEP TO THE...

Page 5: ...THE ASPIRATION 2 VENT 3 CONNECT THE OTHER END OF THE TUBE TO THE VACUUM 3 VENT WITH THE FLOAT ON THE JAR S LID 4 CONNECT THE LONG TUBE 4 TO THE OTHER PATIENT 5 VENT ON THE JAR S LID VENT WITHOUT FLOAT 5 CONNECT THE OTHER END OF THE LONG TUBE 4 TO THE PROBE CONNECTOR 6 AND EVENTUALLY THE SUPPLIED PROBE 7 PRESS THE ON OFF SWITCH 7 8 ASPIRATION INTENSITY CAN BE VARIED WITH THE RELEVANT CONTROL ON THE...

Page 6: ... low battery may damage the appliance itself while continuously recharging it does not cause any damage It is recommended to always check the battery s recharge level LIGHT INDICATOR DESCRIPTION OF THE BATTERY LEVEL LED ON GREEN MAXIMUM CHARGE 2 LED ON YELLOW MEDIUM CHARGE 3 LED ON YELLOW LOW CHARGE 4 LED ON RED NEEDS RECHARGE 5 LED NEXT TO THE BATTERY S CHARGE LEVEL INDICATORS RED WHEN THIS LED I...

Page 7: ...Y WARRANTY ON APPLIANCE THAT UPON INSPECTION BY THE TECHNICAL SERVICE SHOWS SIGNS OF TAMPERING THE OPERATOR MUST EXCLUSIVELY REPLACE THE SUPPLIED ACCESSORIES IF NECESSARY IN LINE WITH THE APPLIANCE S USE INTENSITY ASPIRATION TUBES SHOULD BE STERILIZED AFTER EACH USE IN CASE OF REPAIR THE USER SHOULD CALL FAZZINI S R L TRANSPORTATION COSTS MUST ALWAYS BE AGREED WITH FAZZINI S R L BEFORE SHIPPING FA...

Page 8: ...rvice Manual F 31 doc Rev 2 12 APR 2006 Page 8 of 12 Legenda F 31 xx 1 Filter 2 Vacuum drive 3 Jar drive to the filter 4 Disposable tube to the patient 5 Jar drive to the patient 6 Suction catheter CH 14 7 Main switch 8 Vacuum regulator 9 Vacuum gauge ...

Page 9: ...Suction Unit F 31 S e r v i c e M a n u a l Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 9 of 12 General assembly F 31 xx ...

Page 10: ...Suction Unit F 31 S e r v i c e M a n u a l Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 10 of 12 Functional layout Main Wiring ...

Page 11: ... e r v i c e M a n u a l Doc Service Manual F 31 doc Rev 2 12 APR 2006 Page 11 of 12 Pneumatic circuit 7 6 5 4 3 2 1 1 Catheter to the patient 2 Suction regulator 3 Jar 4 Non rebeathing valve 5 Filter 6 Pump Motor 7 Vent ...

Page 12: ...raph With a multimeter check the voltage between the positive and negative pole if the voltage value is not around 10V dc replace the battery see battery paragraph Situation Possible Cause Solution a Vacuum regulator do not work properly Turn the manifold SP 21 b Internal tubing are not properly connected Open the equipment and verify internal tubing connection c Internal tubing are choked Open th...

Reviews: