4.
Pull the starter rope with the starter handle out completely.
5.
If the starter rope has been torn or the coil has recoiled com-
pletely:
n
Before assembling the rope, turn the coil (2) 5 revolutions
in anti-clockwise direction and align the rope openings in
coil and housing (5) to one another (A).
6.
Secure the coil against winding up. For this purpose tie the
coil (2) to the housing (5) with a cable strap (1).
7.
Untie the knots of the starter rope at both ends and remove
the old starter rope.
8.
Thread in the new starter rope (3) and fix it with knots on
both ends.
9.
CAUTION!
Danger of injury caused by the starter
handle hitting against your body!
–
Do not let the starter handle hit back.
Remove the fixing of the coil and run the starter handle
slowly back to initial position.
10.
Pull the starter handle to check the function and light move-
ment of the recoil starter.
Fig. 88
Fig. 89
Fig. 90
Fig. 91
Maintenance – Annually
DFP8
89
Summary of Contents for DYNAPAC DFP8
Page 6: ...Table of contents DFP8 6 ...
Page 7: ...1 Introduction Introduction DFP8 7 ...
Page 11: ...2 Technical data Technical data DFP8 11 ...
Page 15: ...3 Concerning your safety Concerning your safety DFP8 15 ...
Page 39: ...4 Indicators and control elements Indicators and control elements DFP8 39 ...
Page 45: ...5 Checks prior to start up Checks prior to start up DFP8 45 ...
Page 52: ...Checks prior to start up Checking the water level topping up DFP8 52 ...
Page 53: ...6 Operation Operation DFP8 53 ...
Page 64: ...Operation Parking the machine in secured condition DFP8 64 ...
Page 65: ...7 Loading transporting the machine Loading transporting the machine DFP8 65 ...
Page 69: ...8 Maintenance Maintenance DFP8 69 ...
Page 100: ...Maintenance As required DFP8 100 ...
Page 101: ...9 Troubleshooting Troubleshooting DFP8 101 ...
Page 107: ...10 Disposal Disposal DFP8 107 ...
Page 109: ......
Page 110: ......