3.
Unscrew the fastening screws (1) and disassemble the recoil
starter (2).
4.
Pull the starter rope with the starter handle (1) out com-
pletely.
5.
Secure the coil (2) against winding up.
6.
Loosen the knot (3) in the starter rope and remove the old
starter rope.
7.
Carefully turn the coil back, until the recoil spring is relieved.
8.
Thread in the new starter rope and fix it with knots on both
ends .
A
= 15 mm (0.6 in)
9.
Pre-tension the coil by approx. 4 rotations in direction of
arrow.
Thereby place the starter rope into the recess in the coil .