Maintenance - 1000h
4812158701_G.pdf
2019-10-01
3
6
4
5
2
Fig. Air cleaner
1. Clips
2. Cover
3. Main filter
4. Backup filter
5. Filter housing
6. Dust valve
1
Release the clips (1), pull off the cover (2), and pull out
the main filter (3).
Do not remove the backup filter (4).
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
When replacing the main filter (3), insert a new filter
and refit the air cleaner in the reverse order.
Check the condition of the dust valve (6); replace if
necessary.
When refitting the cover, make sure that the dust valve
is positioned downwards.
Backup filter - Change
Fig. Air filter
1. Backup filter
1
Change the backup filter with a new filter after every
second replacement of the main filter.
To change the backup filter (1), pull the old filter out of
its holder, insert a new filter and reassemble the air
cleaner in the reverse order.
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
134
Summary of Contents for DYNAPAC CA5000
Page 2: ......
Page 12: ...e 4812158701_G pdf 2019 10 01...
Page 16: ...Introduction 4812158701_G pdf 2019 10 01 4...
Page 22: ...Safety Optional 4812158701_G pdf 2019 10 01 10...
Page 26: ...Special instructions 4812158701_G pdf 2019 10 01 14...
Page 70: ...Machine description 4812158701_G pdf 2019 10 01 58...
Page 104: ...Operating instructions Summary 4812158701_G pdf 2019 10 01 92...
Page 106: ...Preventive maintenance 4812158701_G pdf 2019 10 01 94...
Page 116: ...Maintenance 4812158701_G pdf 2019 10 01 Service Checklist 104...
Page 122: ...Maintenance 10h 4812158701_G pdf 2019 10 01 110...
Page 128: ...Maintenance 50h 4812158701_G pdf 2019 10 01 116...
Page 169: ......
Page 170: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...