Scheduled maintenance
68
4812325556EN
08/01/2023
Check the hydraulic oil level
1. Park the roller on a level ground and turn off the engine
2. Check the hydraulic oil reservoir sight glass (1) located on
the right side of the machine.
3. If the oil level is 2 cm below the glass upper line, fill with the
recommended hydraulic oil.
Use only hydraulic oil recommended by
DYNAPAC.
Fill the water tanks
There are two filling caps above the water tank (1).
Loosen and remove the tank lid and fill with a
mixture of water and non-stick in the ratio 9: 1. Do
not remove the filter.
Fill the reservoir with a capacity of 410 liters.
Use as nonstick tire DYNA GUARD. In addition
to protecting the tire is biodegradable.
Check the sprinkler system
Make sure the sprinkler system runs smoothly. The solenoid
valves (5) shall issue a noise to show they are working.
Operate the system and check for clogged nozzles. If necessary,
clean them.
To clean the filter (3) empty the tank (2) and remove the strainer.
Empty the strainer and rinse with water.
Check that the pump (4) is running, listening to their voice or
touching a hand on her.
If there is shut-off valve (6) you will not have to empty the tank
to clean the filter.
Fig.
– Water tank supply
1.
Covers
Fig. - Hydraulic oil reservoir
1. Oil sight glass
2. Filling plug
1
Fig.
– Sprinkler system
1.
Cover
2.
Tank
3.
Filter
4.
Pump
5.
Magnetic valve
6.
Cutting valve
7.
Drain plug
1
2
Fig.: Hydraulic oil reservoir
1- Oil sight glass