8.10.5
Checking the oil level in the exciter housing
NOTICE!
Components may get damaged!
–
Use only oil of the permitted specification
Chapter 8.3 ‘List of fuels and lubricants’
.
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Park the machine on level ground.
2.
Park the machine safely
Chapter 6.4 ‘Parking the machine
in secured condition’ on page 57
3.
Allow the machine to cool down.
4.
Clean the area around the bleeding screw (1) and filling/drain
plug (2).
5.
Unscrew the bleeding screw.
NOTICE!
Components may get damaged!
Do not use low-ash engine oils for the exciter shaft
housing.
6.
Unscrew the filling/drain plug and check the oil level; top up if
necessary.
ð
Nominal value:
Bottom edge of filling/drain bore.
7.
Clean the bleed screw and filling/drain plug and screw them
in with a low-strength sealing agent (e.g. spare parts number:
009 700 16).
8.10.6
Measures prior to extended shut-down period
8.10.6.1
Measures before shutting down
DANGER!
Danger to life caused by explosive gas-air
mixes!
–
Do not allow gasoline to come into contact with
hot components.
–
Smoking and open fire is prohibited.
–
Keep away from heat sources, sparks and
other sources of ignition.
–