15
3 Installation
3.2 EMC compatible installation
Protective measures MCxx 3003 / 3006
Motion Controller
Use environment
Interference type
Action
MCDC 3006 S
Industrial environment Emission
EMC filter
MCBL 3006 S
Industrial environment Emission
EMC filter
MCBL 3006 S
Industrial environment Immunity
EMC suppressor circuit
This table shows which additional EMC measures can be implemented to optimise the behaviour of
the equipment in the intended environment with regard to emission and immunity.
The devices are intended for use in the industrial sector only. If the devices are used in the home, in
business or in commerce or in a small business, appropriate measures must be taken to ensure that
the emitted interference is below the permitted limits!
The EMC filter (for MCDC 3006 S and MCBL 3006 S only)
The supply and motor supply cables must be laid directly on the unit, each with two windings
through a suitable ferrite sleeve (e.g. Würth Elektronik No.: 74270090).
The EMC suppressor circuit (for MCBL 3006 S and MCLM 3006 S only)
The signal cables of the MCBL 3006 S and MCLM 3006 S must be laid directly on the unit with two
windings through a star ring (e.g. Würth Elektronik No.: 7427153).