RS-232 Port and the ASCII Commands
14
Optional Motor Types and Parameters
No.
Motor Type
P-portion (POR)
I-portion (I)
Peak Current (mA)
Continuous Current (mA)
1
1628T012B K1155
3
6
3000
770
2
1628T024B K1155
4
10
3000
410
3
2036U012B K1155
5
6
3000
980
4
2036U024B K1155
6
5
3000
480
5
2444S024B K1155
4
15
5000
1370
6
3056K012B K1155
6
10
7000
1940
7
3056K024B K1155
12
12
3000
930
8
3564K024B K1155
8
20
8000
2800
These parameters can be individually changed or reset to the default parameters of the individual
motor with the command RN.
Important:
By setting the Motor Type other internal parameters will also be changed. Therefore it
is important, when changing motor types on a Motion Controller, to set the type with
the MOTTYP command.