RS-232 Port and the ASCII Commands
12
Saving Configurations
Parameters and configurations
can be saved in an on board
EEPROM chip. That means that
saved programs and configura-
tions are not lost in case of a
loss of power. Upon connec-
tion to the supply voltage the
motor runs under the setup
saved in the EEPROM.
To save parameters in the
EEPROM use the ASCII
Command
EEPSAV.
Important:
Setup can be lost in the case of a loss of power during
programming.
Comments about the command table:
Commands that are marked in the instruction manual with a *)
will be saved with the
EEPSAV
command.
Diagram 4: The operation of the EEPROM
Changing the Baud Rate
The baud rate can be set to the
following values: 1200, 2400,
4800, 9600, 19200 Baud.
Command Function
Description
Example
BAUD *)
Select Baud Rate
Sets the baud rate
BAUD9600
for the RS-232 port
Default Setting: BAUD9600
In order to continue working after the baud rate has been changed
in the motor, the baud rate must also be changed at the PC.
Summary of Contents for MCDC2805 series
Page 58: ...58 Notes ...
Page 59: ...59 Notes ...