26
3.5
3
2.5
2
1.5
1
0.5
0
0
0.5
1
1.5
2
2.5
3
3.5
3
2.5
2
1.5
1
0.5
0
0
0.5
1
1.5
2
2.5
3
Start-up Procedure
Comment
(compare against Measurement 2):
- Reducing resistance R1 the time required for the system to stabilize is increased.
Measurement 6
(output signal)
Diagram 6
Decrease of R1
(
R1
= 56 k
Ω
)
Time
[sec]
Motor
-Speed Monitor
[V]
Diagram 7
Comment
(compare against Measurement 2):
- Increasing capacity C1 increases the damping
(reduction of oscillations before achieving stability).
Increase of C1
(
C1
= 4.7 µF)
Measurement 7
(output signal)
Time
[sec]
Motor
-Speed Monitor
[V]
Specifications subject to change without notice