19
Position Control
Diagram 7: Position control with a reference switch at the analog input
The following Command Sequence is necessary to switch from Speed Control Mode (factory setting)
to Positioning Mode:
SOR0 [enter]
➔
Switches to RS-232 Communication in Speed Control Mode
LR0 [enter]
➔
Load Relative Position 0
M [enter]
➔
Switches to Positioning Mode
Positioning commands:
Command Function
Description
Example
M *)
Initiate Motion
Activates positioning mode and starts positioning
M
LA
Load Absolute Position
Loads the new value for the absolute position.
LA100000
Arguement: 1000 indicates 1 revolution.
LR
Load Relative Position
Loads a new relative position
LR5000
SP *)
Load Maximum Speed
Loads a new maximum velocity.
SP4000
Arguement: rpm from 0 to 30000
AC *)
Load Command
Loads a new value for acceleration.
AC100
Acceleration
Arguement: U/s
2
from 0 to 30000
NP
Notify Position
A “p” will appear on the screen when the motor has
NP10000
rotated beyond a given position.
asynch
➔
p
NV
Notify Velocity
A “v” will appear when a given velocity has been
NV5000
achieved. asynch
➔
v