![FATEK CBEH Manual Download Page 32](http://html.mh-extra.com/html/fatek/cbeh/cbeh_manual_546534032.webp)
32
Station:
Consecutive station number. When the Group Size is specified, its
content will be a fixed network address and consecutive station number
configuration, as shown in the figure below:
Note: The Group’s IP or Station radio button setting is a global setting; it can not be
set entry by entry.
To modify or delete a mapping data, you can press the icons behind the Port
Mapping List field to operate:
The
icon is an edit tool; when pressed, it will change to the
icon, and the
highlighted parts will turn red, then you can modify above the field and then press
Apply to complete the modification. To delete a data, click the
icon directly to
delete the mapping data.
3.2.6 Service Port
The service ports must first be set before the server function of this expansion board
can operate; the external client-ends will use this service port to send connection
requests to the CBEH module and so the messages can be received by this expansion
board.
CBEH’s default FATEK communication protocol service port is 500, Modbus’
communication protocol service port is 502, Http communication protocol service
port is 80. A maximum of 2 service port numbers can be provided to each service at
the same time, in which one is a fixed default port and the other is a modifiable port.
If the user wants to modify the modifiable service port, the Service Ports setting page
can be used to make the modification. While modifying, just enter the port number
you want to modify into the Major Port field.
Summary of Contents for CBEH
Page 1: ...Ethernet Communication Board CBEH CBEH 0A CBEH 2A ...
Page 44: ...44 ...