New Classic Edition 2.0
FASTTEL Klipsenstraat 18A 9160 Lokeren
Tel : + 32 (0) 9 244 65 20 FAX:+ 32 (0) 9 244 65 29 Email:
Web :
WWW.FASTTEL.BE
15
Code
2 12
letter
#
2 13
letter
A
2 14
letter
B
2 15
letter
C
Code
2 16
letter
D
Attention !
If the “end of conversation” code is the same as the code for operating the (door) contact, dan the
door contact will automatically be first operated, and then the connection will be ended.
Extra function
The wizard classic has thus 1 relay on board. The user can activate this relay by pushing the 2 on his
telephone keypad. If the user desires more than 1 relay or/and he wishes not to have the relay at the
outside in the door phone the FT4SW or FT8SW offers the solution. These modules offer 4 and 8
extra relays safely in the house. Normally these relays are activated via the telephone keypad
forming the codes #001 for raly 1 up to #008 for relay 8.
But you can chose anyway to activate 1 relay of the FT4SW or FT8SW by forming the short code 2.
Code 2: use code 936ab where a= address FT4SW or FT8SW (if a=* the internal relay of the door
phone will be activated (default))
b= relay
attention: to be able to connect the FT4SW or FT8SW the plug in board FT29LON must be ordered.
12. Setting max. conversation time
This setting sets the maximum conversation time. After this time the Wizard will end the
conversation automatically.
This conversation time can be set in steps of 5 seconds and can be multiplied by 01 to 99.
How ?
Code
80 xx
value to be set
Code
80 00
maximum conversation time (60 minutes)
Code
80 24
conversation time 24 x 5 seconds= 2 minutes (default)
Code
80 50
conversation time 50 x 5 seconds = 250 seconds or 4 minutes, 10 seconds.
13. Setting push time button
This setting allows you to settle the push time needed before the call will be made.
Remark: only for the models without key board.
How?
Code
931AB
where AB stands for the number of steps of 0,1 seconds.
e.g
93101 = 100 msec (=default)
93110 = 1 second
14. Setting toggle/impulse contact
With this setting, you can choose between toggle (on/off) contact or impulse contact.
New Classic Edition 2.0
FASTTEL Klipsenstraat 18A 9160 Lokeren
Tel : + 32 (0) 9 244 65 20 FAX:+ 32 (0) 9 244 65 29 Email:
Web :
WWW.FASTTEL.BE
16
This setting is useful if you use the contact for operating the doorlock.
You can choose toggle if you want to operate an on/off switch
How ?
Code
6 10
Impulse contact (door lock)
Code
6 11
Toggle contact
15. Setting time (door) contact
This setting sets the time of the (door) contact.
When using the door contact, it is advised to activate the lock +/- one second.
Or you can operate a light and set a timer in 5 second steps.
These steps can be set from 01 to 99.
How ?
Code
81 00
contact not active
Code
81 01
time duration one step (5 seconds or 100 msec.) consult setting contact
steps
Code
81 99
time duration 99 steps
eg.
Steps 5 seconds
8112 = 12 x 5 seconds = 60 seconds
eg.
Steps 100 msec.
8112 = 12 x 100 mseconds . 1200 msec.
16. Setting contact steps 5 sec./100 msec.
You can set the contact in steps of either 5 seconds or 100 msec.
When using the doorlock it is advised that you set the contact in steps of 100 msec.
You can then set the code 81 xx to 10 (1 second).
If you choose to switch on a light, you can choose the 5 seconds steps.
You can then use the contact as a timer contact.
How ?
Code
5 20
contact in steps of 5 seconds max. = 99 x 5 sec. = 8 min. 15 sec.
Code
5 21
contact in steps of 100 msec. max. = 99 x 100 msec. = 9.9 sec.
17. Setting loudspeaker level and micro sensitivity
This setting allows you to adjust the loudspeaker level and micro sensitivity to a default
level at the installation of the Wizard.
How ?
The installer sets the level via : code
88
XX
XX =value between 00 and 15.