30
No : Alarm input number
Priority : The lower number has higher priority. (1-8)
Function : Stored function number to be called by alarm.
In : NO/NC - normally open /Closed OFF - ignore
Out : OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.
Hold : Alarm will be held for programmed time (03 to 99 seconds)
Latch : ON - Shows all alarms including past alarm.
OFF - Shows activated alarms only.
Dwell : means the dwell time during multiple alarms, 03 to 99 seconds.
The RELAY OUT setup is helpful when the outdoor housing is used with the dome.
Ex.) When you connect the relay output of the dome to the heater connector of the outdoor
housing, the relay output can operate during the setting time only.
Alarm: the relay output is operated during an alarm operation or by the short key of our
keyboard.
1-5 MIN (minute): the relay output is operated during this setting time only by the function
run of the dome menu or the short key of our keyboard.
Note : This 1-5 MIN setting is not operated by an alarm.
Note : If you disable Alarm by dip switch, Alarm menu will be displayed following
screen.