LED Name
Description
State
Indication
EMS REQ
EMS request
On
EMS module request for heater to run.
Heater only acts on this request if in AUTO mode.
POWER
Power supply
On
Controller energized.
MOTOR
Motor
On
Contactor closed, motor turned on.
HEAT
Controller
request for heat
On
FSR requested. Ignition sequence started or burner operating.
RUN IND
Heater run
indication
On
Indication contact closed. Turns on after 60 seconds of normal operation.
ALARM
Heater alarm
indication
On
Alarm indication contact closed. Heater off and locked out. Controller must be
reset manually.
FSR ALARM
Flame safety
relay alarm
On
FSR in ALARM, or controller is preventing its operation.
Alternating
FSR is in ALARM. Heater failed 4 times in 5 minutes.
AIR SW
Air pressure
switch
On
Contact closed. Sufficient air flow to allow burner operation.
Alternating
Air switch did not operate as intended. Air switch either did not close with fan ON
or did not open with fan OFF.
Off with pulse on
Continuous fan mode with selector switch in OFF position.
On with pulse off
Continuous fan mode with selector switch in MANUAL or REMOTE/AUTO
position.
CYCLING
Cycling
thermostat
On
Thermostat closed. Heated air temperature is BELOW set point.
Alternating
Cycling thermostat open for more than 10 minutes.
HIGH LIM
High limit
thermostat
On
Thermostat closed. Heated air temperature ABOVE set point.
Alternating
High limit thermostat closed momentarily indicating air temperature exceeded
set point.
MANUAL
Manual operation On
Selector switch in “MANUAL” position. Heater in MANUAL mode.
RAIL TH
Rail thermostat
On
Thermostat open. Rail temperature is BELOW set point.
RTC
Rail traffic control
mode
On
Indicates selector switch is in “REMOTE/AUTO” position and AAR terminals 1
and 2 are closed.
Off with pulse on
Indicates selector switch is in “REMOTE/AUTO” position and requested by
RCMS.
On with pulse off
Indicates selector switch is in “REMOTE/AUTO” position and requested by
RCMS and AAR terminals 1 and 2 are closed.
E.5 Terminal Blocks
1.
The controller interconnects with the control panel by means of 8 board level headers, TB1 to TB8, which accept the various
wire harness plug connectors. The controller and EMS module connect via a ribbon cable that plugs into the 10-pin header
found on each.
Table 6 – Terminal Block Description
Name
Description
JP1
Jumper. Used to configure EEPROM settings
TB1
120V power, transformer primary and motor contactor coil output
TB2
Transformer secondary 24V power and FSR request output
TB3
RTC run and alarm indication contacts outputs
TB4
Rail thermostat, RTC request, Manual, and Enable inputs
TB5
Air switch, FSR/DSI alarm, gas valve inputs
TB6
Cycling and high limit thermostats inputs
TB7
Communication port, RS-485
TB8
FSR reset and current transformer inputs
10-pin header*
EMS module power and signal connection
*Located in the upper right corner next to TB8.
Summary of Contents for Hellfire 900
Page 26: ...26 26 Figure 3 155 Clearance Figure 2 140 Clearance Installation...
Page 27: ...27 27 Figure 4 155 Clearance Turned 90 Degrees Installation...
Page 37: ...37 37 Heater Specifications THERMON HEATING SYSTEMS INC H 9 SchematicsMaintenance...
Page 38: ...38 38 Heater Specifications THERMON HEATING SYSTEMS INC...
Page 39: ...39 39 Heater Specifications THERMON HEATING SYSTEMS INC...
Page 40: ...40 40 Heater Specifications THERMON HEATING SYSTEMS INC...
Page 41: ...41 41 Heater Specifications THERMON HEATING SYSTEMS INC...
Page 42: ...42 42 Heater Specifications THERMON HEATING SYSTEMS INC...
Page 54: ...54 54 NOTES...
Page 55: ...55 55 NOTES...