NOTE:
Check that the Basket Hanger has been correctly
fitted. The Basket Hanger should clip over the front
of the splash back and not over the flue outlet as
this will restrict the operation of the flue.
1. This appliance must be installed in a suitably
ventilated room to prevent dangerous build up
of combustion products.
2. Installation must allow for a sufficient flow of
fresh air for the combustion air supply.
Combustion Air Requirements
Natural Gas
24 m³/hr minimum.
LPG / Butane
24 m³/hr minimum.
Town Gas
24 m³/hr minimum.
3. Position the appliance in its approximate
working position.
4. All air for burner combustion is supplied from
underneath the appliance. The legs must
always be fitted and no obstructions placed on
the underside or around the base of the
appliance, as obstructions will cause incorrect
operation and / or failure of the appliance.
5. Components having adjustments protected
(e.g. paint sealed) by manufacturer are only
allowed to be adjusted by a qualified service
agent. They are not to be adjusted by the
installation person.
NOTE:
Do not obstruct or block the appliances flue. Never
directly connect a ventilation system to the
appliance flue outlet.
NOTE:
It is most important that this appliance is installed
correctly and that operation is correct before use.
Installation shall comply with local, gas, health and
safety requirements.
This appliance shall be installed with sufficient
ventilation to prevent the occurrence of
unacceptable concentrations of health harmful
substances in the room, the appliance is installed in.
FastFri gas fryers are designed to provide years of
satisfactory service and correct installation is
essential to achieve the best performance,
efficiency and trouble-free operation.
This appliance must be installed in accordance with
National installation codes and in addition, in
accordance with relevant National / Local codes
covering gas and fire safety.
Australia/New Zealand:
AS/NZS 5601- Gas Installations.
United Kingdom:
Gas Safety (Installation and
Use) Regulations 1998.
Ireland:
IS 820 - Non Domestic Gas
Installations.
Installations must be carried out by qualified service
persons only. Failure to install equipment to the
relevant codes and manufacturer’s specifications
shown in this section will void the warranty.
Components having adjustments protected (e.g.
paint sealed) by manufacturer, are only to be
adjusted by a qualified service agent. They are not
to be adjusted by the installation person.
Remove all packaging and transit protection
from the appliance including all protective
plastic coating from the door outer panel and
exterior stainless steel panels.
Check equipment and parts for damage.
Report any damage immediately to the carrier
and distributor.
Report any deficiencies to the distributor who
supplied the appliance.
Check that the available gas supply is correct to
that shown on the rating plate located on the
inside of the access door.
Check that the following parts have been
supplied with the appliance:-
Baskets
2
Basket Hanger
1
Basket Tray
1
Lid
1
Drain Extension
1
Basket
Hanger
Fitted position of