Providing Pumping Solutions
www.fastflo.co.nz |
Call Free: 0800 327 835
9
TYPICAL PLUMBING INSTALLATION
Installation Notes:
y
Ground level should be sloping away from tank to avoid ponding and floatation of pump station
y
Position tank at the lowest part of drainage system or in a position appropriate to drainage system.
y
Drill gravity inlet and discharge pipe between ribs of pump chamber at a height to suit the on-site conditions.
y
Control Panel to be mounted on wall in a position within close proximity to pump station
y
Tank to be backfilled with compatable material in 300mm layers.
y
Must have a concrete plug in high water table areas.
Road
Council Drain or
Manhole
Discharge pipe
(PE or PVC)
PE acess lid
Gravity Drain
PE Holding Tank
Sub Pump
Allow for concrete plug in high
water table areas
Cohesive Backfill
(compacted in 300mm layers)
100mm Sub Base
(compacted - fine grade scoria or similar)
VENT (Option 1)
80mm vent pipe vented
to atmosphere.
(If 80mm TV not available)
VENT (Option 2)
80mm TV
OR