Providing Pumping Solutions
www.fastflo.co.nz |
Call Free: 0800 327 835
17
TYPICAL ELECTRICAL INSTALLATION SCHEMATIC
Notes:
y
32mm conduit (to be sealed at both ends to prevent gas entry)
y
1x2 core + E pump cable 2.5mm
2
circular
y
1x3 core alarm cable 0.75mm
2
circular
y
1x 4 core security cable from Controller to Alarm Plate inside
y
Max length of pump cable = 8m
y
Max length of alarm cable = 8m
y
If pump station is to be further than 6m from house, pump and control cables will need to be extended -
ensure joint is waterproof.
y
No cable joints are permitted in conduit.
32mm conduit
Pump Float (on/off)
Pump Cable
Control
Box
Sub Pump
PE Pump Chamber
HL Alarm Float
230V in
• 2-Core + Earth
• Minimuim 2.5mm
2
• 20 AMP
4 Core
security
cable
Alarm plate (fits into
standard electrical
flush box)