www.fastech.co.kr - 56
Flash
Times
Alarm
Contents
Conditions
The Cause of Error
Checking Point
Corrective Measure
8
Encoder
Connect
Error
An error with
the connec-
tion between
the drive and
the encoder
If the encoder extension ca-
ble is damaged
Checking the connection status
of motor and the extension
cable of encoder.
① Make sure connection of
cable connector.
Checking if the extension cable
of encoder is disconnected.
① Replace the extension cable
of encoder.
Checking the wiring status of
the extension cable of encoder.
① Fix the extension cable of
encoder.
② If same alarm is generated
after correction, drive and motor
may have damaged by faulty
cable, so replace the motor and
drive.
The encoder may have
problem
Checking if the encoder is
damaged, unscrew or
extension cable of encoder
is disconnected. (Can not be
checked when assembled)
① Replace the motor.
The drive may have problem
① If Alarm keep blinking after
tried all of above, replace the
drive.