6. EtherCAT Object Dictionary
POR Operating Time
It displays the time [s] that has elapsed after the controller was recently powered up.
POR Enable Time
It displays the time [s] the drive has been in Operation Enabled after the controller was recently powered
up.
POR Rotating Count
It displays the number of revolutions the motor has rotated through the command after the controller was
recently powered up.
LTR2 Operating Time
Same as Sub-Index 1 - LTR Operating Time, it displays the total time it has been powered on and
operated. It can be initialized through the LTR2 Function.
LTR2 Enable Time
Same as Sub-Index 2 - LTR Enable Time, it displays the total time it has been powered on and the drive
is the Operation enabled state. It can be initialized through the LTR2 Function.
LTR2 Rotating Count
Same as Sub-Index 3 - Rotating Count, it displays the total number of revolutions the motor has rotated
through the command. It can be initialized through the LTR2 Function.
LTR2 Function
By writing 00726C63h in LTR2 Function object, LTR2 Operating Time, LTR2 Enable Time, LTR2 Rotating
Count can be initialized.
When the initialization command is written, the values of the above three objects are immediately cleared
to 0, and the data is accumulated again from that time.
6.6.19
Object 2030h: Advanced settings
Sub
PDO
Value
Default
Index
index
Name
Type
Access
SAVE
Mapping
Range
Value
2030h
0
Number of entries
U8
RO
No
No
5
1
Automatic recovery from
communication error
U8
RW
Yes
No
0
∼
1
0
2
Disable Automatic transition
2
U8
RW
Yes
No
0
∼
1
0
3
Config Internal Limit Active
bit
U8
RW
Yes
No
0
∼
1
0
4
Enable Packet Delay
Compensation
U8
RW
Yes
No
0
∼
1
1
5
Transit to Fault state when
Safety activated
U8
RW
Yes
No
0
∼
1
0
Automatic Recovery from Communication Error
This object can set ’EtherCAT communication error (7500h)’ to be clear when EtherCAT communication
status is activated again. If the value is set to 1, the ’EtherCAT communication error (7500h)’ is automat-
ically cleard when the state of EtherCAT State Machine changes from Safe-Operational to Operational.
Disable Automatic transition 2
This object can set whether ’Transition 2’ of Drive State Machine occurs automatically or not. If the value
is set to 1, Transition 2 will not occur automatically, but rather through the ’Shutdown’ command.
Rev.37
FASTECH Co., Ltd.
90
Summary of Contents for Ezi-STEPII EtherCAT MINI
Page 10: ...Chapter 1 Product Specification Rev 37 FASTECH Co Ltd 10 ...
Page 14: ...Chapter 2 Installation Rev 37 FASTECH Co Ltd 14 ...
Page 25: ...Chapter 3 EtherCAT Communication Rev 37 FASTECH Co Ltd 25 ...
Page 31: ...Chapter 4 CiA402 Drive Profile Rev 37 FASTECH Co Ltd 31 ...
Page 55: ...Chapter 5 Operation Rev 37 FASTECH Co Ltd 55 ...
Page 59: ...Chapter 6 EtherCAT Object Dictionary Rev 37 FASTECH Co Ltd 59 ...