9.
Clean all debris from exterior and interior of hose.
10.
All lines should be tested to twice their operation pressure prior to use.
Section 4 - Electrical Installation
1.
Find a suitable place to mount the supplied relay, the relay is typically mounted by the OEM
fuel pump wiring connector
(Never mount the relay inside of the fuel tank or next to fuel
tank vents!)
. Ensure the relay and any associated parts are clear of the exhaust, any moving
suspension or drivetrain components and any possible road obstructions or debris.
2.
Attach the OEM fuel pump wires to relay terminals 85 and 86 using two of the supplied blue
female blade connectors (See Figure Below).
Note: Be sure to route all electrical wires clear of any moving suspension or drivetrain
components, and any exhaust components! Protect wires from abrasion and road
obstructions or debris.
3.
Find a suitable location for mounting the supplied circuit breaker. For optimal circuit
protection, the circuit breaker needs to be mounted as close to the battery as possible.
4.
Connect terminal number 30 on the relay to the circuit breaker by using the supplied red 10 ga.
wire, one of the yellow female blade connectors on the relay end of the wire and one of the
yellow #10 ring connectors on the circuit breaker side of the wire.
Note: Be sure to route all electrical wires clear of any moving suspension or drivetrain
components and any exhaust components! Protect wires from abrasion and road
obstructions or debris.
5.
Connect terminal number 87 on the relay to the positive terminal on the fuel pump. This is
accomplished by using the supplied red 10 gauge wire, one of the yellow female blade
connectors on the relay side of the wire and one of the yellow #10 ring connectors on the fuel
pump side of the wire.
6.
Connect the negative terminal on the fuel pump to a clean chassis ground using the supplied
black 10 gauge wire and two yellow #10 ring connectors.
7.
Connect 12VDC to the circuit breaker using the supplied red wire and one of the yellow #10
ring connectors and the supplied yellow 3/8” ring connector.
8.
Ensure that electrical components and wires are connected properly (See Figure 4-1) and are
clear of any moving suspension or drivetrain components and any exhaust components! Protect
wires from abrasion and road obstructions or debris.