background image

Fast & Fluid Management – SK350 

V 2.0-2015

    

  

                                page 5 

 

Safety instructions 

 

General safety instructions 

 

 

Attention! Before installing the equipment and setting it in operation, 
please read the instructions carefully. This is safer both for yourself 
and prevents unnecessary damage to the machine. 

 

The manufacturer accepts no liability if the instructions below are not followed: 
 

1. 

If a machine has been damaged (during transport, for example), do not attempt to set it in 
operation. When in doubt, first contact either your supplier or the F&FM service 
department.

 

2. 

The equipment should be positioned and connected up in strict accordance with the 
installation instructions.

 

3. 

All local safety regulations and ordinances should be observed.

 

4. 

The machine may be connected only to a 220-240V/16A/50Hz earthed wall socket installed 

in accordance with the regulations.

 

5. 

Users should see to it that the machine is kept in good condition. Defective components 

should be replaced.

 

6. 

In order to prevent physical injury, the doors should be closed and the paneling fitted 
during normal use.

 

7. 

All service activities (other than routine maintenance and adjustments) may only be carried 
out by qualified technicians. See to it that the mains lead is always kept unplugged while 

repairs are being carried out.

 

 

Specific safety instructions in this manual 

 

 

Attention! Failure to remove the frame lock correctly can result in 
severe damage to your SK350 when in operation. Please take care! 

 

 

Attention! To prevent damage, the SK350 may only be connected to 
either 220-240V/16A/50Hz power grids. 

 

 

Attention! Only use the emergency stop button in case of a true 

emergency. After pressing the emergency stop, wait at least 15 
seconds before unlocking it (turn clockwise). The SK350 will then 
reset and unclamp the container. 

 

 

Attention! MOVING PARTS CAN CAUSE INJURY. Always turn off power 
(e.g. by pressing emergency stop) before accessing moving parts. 

 

  

Summary of Contents for SK350

Page 1: ...Fast Fluid Management SK350 V 2 0 2015 page 1 FAST FLUID MANAGEMENT SK350 ENGLISH...

Page 2: ...ertification Pag 3 Main SK350 components Pag 4 Safety instructions Pag 5 Installation Pag 6 8 Operation Pag 9 12 Maintenance Pag 13 Problem solving Pag 14 15 Service and Support Fuses Pag 15 Specifica...

Page 3: ...nditions referred to in point 6 of the general conditions of sale The warranty obligation described in this article only applies if the goods supplied by F FM have been used in accordance with the man...

Page 4: ...op lid 2 Keyboard Emergency stop button 3 Transformer 4 Power Board 5 Removable front panel 6 Clamping plate 7 Super strut suspension 8 Door handle 9 Shaker frame 10 Can table 11 Can mounting rim 12 E...

Page 5: ...Users should see to it that the machine is kept in good condition Defective components should be replaced 6 In order to prevent physical injury the doors should be closed and the paneling fitted duri...

Page 6: ...le unpacking it Take care not to accidentally close the door before finishing installation as it can then only be unlocked power on the machine Step 2 Remove the frame lock Pull out cord to remove fra...

Page 7: ...d lock the adjustable feet Tip before locking the adjustable feet start a mixing cycle with a small load 5kg While the SK350 runs check if all four feet are firmly in contact with the floor and then l...

Page 8: ...Step 5 Electrical connection Connect the power cable to the socket at the rear of the machine Ensure the emergency stop is unlocked turn clockwise Attention To prevent damage the SK350 may only be con...

Page 9: ...r is plugged into a 220 240V wall socket The power led lighted ON The machine is in stand by modus To awake the machine from its sleeping modus press any of the interface buttons Please note that duri...

Page 10: ...ational center of the can table between the spindles Place filler disc on lid to prevent displacement during operation Remove the can handle before shaking When mixing more than one can use adhesive t...

Page 11: ...t start unless the door is closed Step 2 Program ends or is interrupted remove can To interrupt the mixing program press the stop button Use the emergency stop only in case of a true emergency When th...

Page 12: ...amp the container immediately the shaking starts for the setting time After the shaking period the machine shall stop and will move the clamping plate automatically upwards Before opening the door and...

Page 13: ...parts especially clamping plate spindles Use diluted detergent only and Teflon spray only Though the SK350 is designed to be completely maintenance free periodic greasing of moving parts will ensure i...

Page 14: ...ergency stop is active Turn emergency stop clockwise Machine is overloaded Unload max 35 kg Fuse blown on the socket Shut power off and replace fuse see page 15 Door switch is defective Call service K...

Page 15: ...ntainer s in gravitational centre Service and Support If necessary you can get in touch with your supplier or the local service department or contact the manufacturer directly If you contact the manuf...

Page 16: ...ue 300Kg Product access Internal sliding door Shaking speed 700 rpm Large can table standard Machine size H x W x D 116 x 72 x 61 cm Machine weight empty 180 kg Power input 750W Power supply 220 240V...

Page 17: ...Fast Fluid Management SK350 V 2 0 2015 page 17 Electrical wiring diagram...

Page 18: ...ur hands Discarding the Machine Discarded equipment usually still consists of valuable materials For this reason do not simply throw your machine out with the oversized refuse but ask your supplier wh...

Page 19: ...Fast Fluid Management SK350 V 2 0 2015 page 19 Fast Fluid Management B V 2015 www Fast Fluid com...