TROUBLE SHOOTING
CAUTION :
In case of unexpected failure, electrically insulate the machine by means of an
omni polar disconnection device.
TURNTABLE NOT TURNING :
.
Feeding plug not connected or defective:
- check the plug
Machine not powered:
- Restore the electric connections.
Defective inverter :
- replace the inverter, (skilled staff needed in this case)
Motor shorted:
- replace the motor, (skilled staff needed in this case)
Belt broken:
- Replace the belt
ROTATION CONTROL PEDAL FAILS TO RETURN TO CENTRAL POSITION:
.
Control spring broken:
- Replace the control spring.
BEAD BREAKER PEDAL AND TABLE TOP PEDAL DO NOT RETURN TO HOME POSITION :
.
Control spring broken:
- Renew the spring.
No oil in lubricator:
- Top up lubricator with SAE20 non-detergent oil .
AIR LEACK INSIDE THE MACHINE :
.
Air leak from bead breaker cock:
- Renew the cock.
- Renew bead breaker cylinder.
Air leak from the table top cock:
- Renew table cock unions.
- Replace the cock.
25
COLUMN TILTS VIOLENTLY OR TOO SLOWLY :
.
Incorrect release valve setting:
- Adjust air delivery regulators on control valve.
ELECTICAL BEAD BREAKER MOTOR NOT OPERATE :
.
Blown fuses:
- Replace the fuses type 10,3x38 16 A.
Defective inverter :
- Replace the inverter, (skilled staff needed in this case)
Motor shorted:
- Replace the motor, (skilled staff needed in this case)
Limit microswitch defective:
- Replace the limit microswitch , (skilled staff needed in this case)
Summary of Contents for RASE.TOP.2248
Page 13: ...DECALCOMANIE 13 9 10 1 2 3 4 9 23 8 5 6 10 11 12 13 18 14 15 16 17 17 19 20 21 22 7...
Page 38: ...LABELS 13 9 10 1 2 3 4 9 23 8 5 6 10 11 12 13 18 14 15 16 17 17 19 20 21 22 7...
Page 52: ...SCHEMA ELETTRICO ELECTRIC SCHEME 27 S 40 2 P...
Page 53: ...28 SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 P...
Page 54: ...SCHEMA ELETTRICO ELECTRIC SCHEME S 40 2 E 29...