MAINTENANCE
CAUTION :
The “spare parts” handbook does not authorize users to carry out work on the
machine with the exception of those expressly described in the user manual. It
only enables users to provide the technical assistance service with precise in-
formation in order to minimize delays.
WARNING :
Fasep
srl declines all liability for claims deriving from the use of non-original
spare parts or accessories.
CAUTION :
Any operation intended to modify the setting value of the relief valves or pres-
sure limiter is forbidden .
Fasep
srl declines all liability for damage resulting from tampering with the-
se valves.
CAUTION:
In case of replacement of the power supply cable, follow the indications listed
in the table below for the most appropriate cable choice:
SUPPLY
CABLE TYPE
N° OF WIRES
WIRE SECTION
400/3/50
400/3/60
230/3/50
230/3/60
200/3/50
200/3/60
FROR 450-750 V
UNEL 35011
H07RN-F
CEI 20-27
3 - phase
1– gounding
1 mm²
240/1/50
230/1/50
220/1/60
FROR 450-750 V
UNEL 35011
H07RN-F
CEI 20-27
1— phase
1—neutral
1—grounding
1,5 mm²
115/1/60
UL 1569 300V
105°C
1— phase
1—neutral
1—grounding
AWG 14
CAUTION :
Do not remove or modify any parts of this equipment except in the case of ser-
vice operations.
19
Summary of Contents for RASE.2234
Page 13: ...DECALCOMANIE 1 2 3 4 10 11 12 13 15 16 17 14 9 8 7 6 5 9 10 13...
Page 36: ...LABELS 1 2 3 4 10 11 12 13 15 16 17 14 9 8 7 6 5 9 10 13...
Page 48: ...SCHEMA ELETTRICO 220 V 1 ph 50 Hz 1 speed 25 SCHEMA ELETTRICO 400 V 3 ph 50 Hz 1 speed...