Fasep 2000 srl
Rev. 1.8
Balatron 222/212: User’s Manual
23 January 2020
4-2
F
IG
.
14
F
IG
.
15
4.2
How to check the calibration of Wheel Balancer (USER)
ATTENTION
select mode
CAL USR
Press <+/-> to select CAL TEST
Place a wheel on the flange ( Fig. 13).
Put the calibration weight ( Fig. 14).
Press
10 <FINE>
to see actual values.
160-0 (±3) is correct result.
When all LED (left side) are lit,
calibration weight must be at exactly 6
o’clock.
If no, press
11 <FUNC>
to calibrate
position.
Turn the wheel until the calibration
weight is located at 6 o’clock.
Press
<SET>
to calibrate.
Press
<MODE/ESC>
to return to normal
balancing mode.
NOTE
technical calibration is only available for qualified personnel.
F
IG
.
16
Summary of Contents for B222
Page 1: ...www fasep it User s MANUAL B222 B212 B112...
Page 20: ......