![Fasep B222 User Manual Download Page 14](http://html1.mh-extra.com/html/fasep/b222/b222_user-manual_3529927014.webp)
Fasep 2000 srl
Rev. 1.8
Balatron 222/212: User’s Manual
23 January 2020
5-4
F
IG
.
34
: inside weight indication
F
IG
.
35
: outside weight indication
F
IG
.
37
F
IG
.
38
5.4
Detecting and correcting unbalance
5.4.1
After setting wheel dimensions, press
<START>
or close the safety cover (optional) to spin the wheel and start the
measurement run.
!
CAUTION
Wheel start automatically when safety cover is closed.
5.4.2
At the end of the spin the wheel will brake automatically and the display will show the weight position and weight
requirement to correct the wheel’s unbalance.
5.4.3
If unbalance shown is
GOOD
, press
10 <FINE>
to show residual unbalance.
NOTE
OPT light blinking after the measurement indicates that static unbalance is exceeding more than 20grs.
Optimization procedure is suggested.
5.5
How to apply the weight using ALU-SE indicator
Place the weight (Fig. 37).
Turn the wheel to the position ( Fig. 34,
Fig. 35).
Move the rod until
///
appears on the
display ( picture on the left).
Apply the weight ( Fig. 38).