6.0 Range
3
Read range between the Transmitter and Receiver depends on the Receiver model being used. Please review the Ranger Receiver datasheet for
more information.
7.0 Troubleshooting
Issue/Possible Cause
Corrective Action
No data received/Transmitter not enrolled
Transmitter must be clicked twice to be learned by the Receiver upon initial Receiver power up
Short read range/Receiver potentiometer
Adjustable potentiometer should be set to the maximum setting (certain models only)
Some buttons not working/Receiver capability
Receiver Model WRR-22 only works with buttons 1 and 2
Prox insert not working/Compatibility
Support with HID
®
and AWID
®
125-kHz Proximity Protocol readers must be requested on PO
With WRT-2M, does not include a proximity or contactless smartcard module. Adhesive disk
tags are sold separately.
Red LED does not flash upon button press
Check that battery is installed correctly and is not dead (fully discharged)
Should any of the corrective actions mentioned above not improve performance, please contact Farpointe directly.
1. This lithium battery is widely available, and commonly used in electronic devices, including cameras and remote controls.
2. Dispose of the battery according to local requirements. Recycle when possible.
3. For best performance the Transmitter should be used as far from interference sources as possible. These sources may include, but are not limited to, large metal
obstructions, such as duct work and appliances, as well as magnetic fields and radio emissions.
Many Farpointe Data Readers carry the following certifications:
P
/N
: 0
16
0
2
-0
01 ∙ R
ev
. 0
1.
19
© 2012-2019 Farpointe Data, Inc. All rights reserved. Farpointe Data
®
, Pyramid
Series Proximity
®
, Delta
®
, and Ranger
®
are the registered U.S. trademarks of
Farpointe Data, Inc. Conekt is a trademark of Farpointe Data, Inc. MIFARE is a
registered trademark of NXP B.V. AWID is a registered trademark of Applied
Wireless Identifications Group. HID and the HID logo are registered trademarks of
HID Global Corporation, an ASSA ABLOY company. All other trademarks are the
property of their respective owners.
QUICK START GUIDE
433-MHz RANGER
®
LONG-RANGE
WRT-2+/WRT-4+/WRT-2M WIRELESS RADIO TRANSMITTERS
www.farpointedata.com
Farpointe Data, Inc.
2195 Zanker Road
San Jose, CA 95131 USA
Office: +1-408-731-8700
Fax: +1-408-731-8705
[email protected]
FCC Compliance Statement: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by Farpointe Data could
void the user's authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union
coun-tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain,
Sweden, United Kingdom, as well as other non-EU countries, including Iceland,
Norway, and Switzerland.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause unde-sired operation of the device.
Cet appareil est conforme à Industrie Canada exempts de licence standard RSS (s).
Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne
peut pas provoquer d’interférences et (2) ce dispositif doit accepter toute
interférence, y compris les interférences qui peuvent causer un mauvais
fonctionnement du dispositif.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Farpointe Data reserves the right to
change specifications without notice.