- 66 -
Manifold Assembly
M4 with washer (3 pcs)
Manifold Assembly
M4 with washer (3 pcs)
M4
×
7 pcs
M4
×
7 pcs
INSTRUCTIONS FOR CONVERSION
Instructions for converting the MWH180 from nat. gas to LP gas or LP gas to nat. gas.
DANGER:
Serious injury or death can result to individuals who are not licensed professionals
properly trained in performing conversions. Proper tools and safety gear are always required.
If you are not a professional trained in conversions do not attempt to perform a conversion.
WARNING:
This conversion should only be performed by a qualified gas company, plumber,
HVAC technician, or trained service person familiar with gas fired equipment. This person
should have tools to perform the conversion, check gas pressures, re-adjust gas pressures if
necessary, and leak test the unit once the conversion is complete.
To conver t to Natural gas you will need to contact your local MWH supplier and order
part# 3724-2 Damper and part# 3722-2 Manifold Assembly. For conversion to Propane part#
3724-1 Damper and part# 3722-1 Manifold Assembly will be needed.
WARNING:
If you do not follow these instructions
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
MPI P/N
3722-1
3722-2
3724-1
3724-2
Description
Manifold Assembly (Propane Gas)
Manifold Assembly (Natural Gas)
Damper (Propane Gas)
Damper (Natural Gas)
Illustration
Procedure
Step 1:
(1) Remove the four screws from front panel,
and place on the side so that they not get
lost or damaged.
(2) Remove wires from flame sensor and
electrode.
(3) Remove the set screws fixing the
Manifold Assembly (M4
×
7pcs, M4 with
washer
×
3pcs ).
(4) Remove Manifold Assembly by gently
pulling it from both sides. Once Manifold is
removed make sure that the two O-rings that
seal between the Manifold and gas valve are
fixed in their groved surfaces. Should an
O-ring stick to the Manifold or drop out,
gently peal off the O-ring, inspect both
O-rings to make sure they are clean and not
damaged, then reinsert into groves in the
Gas Control Assembly. If either O-ring is
damaged it should not be reused but
replaced.