Inputs
INPUTS
The Jackal has the following available selectable inputs
FRONT SCREEN > SETUP > INPUTS
Meter / Pulse (M)
Feet / Pulse (FT)
Yard / Pulse (YD)
Inch / Pulse (IN)
Kilometer / Pulse (KM)
Mile / Pulse (MI)
Pulse / Kilogram (KG) Pulse / US Pound (LB)
Pulse / Litre (L)
Pulse / US Gallon (GAL)
Pulse / Bushel (BU)
Pulse / Rev (RPM)
Pulse / Bale (BALE)
Pulse / Unit (UNIT)
Pulse / Each (EACH)
13 Inputs are available on the Jackal
Refer to Page 3 for input usage
After selecting your input pressing the EDIT key allows
you to enable/disable the port
CALIBRATION METHOD – TARGET & MANUAL RATIO
When the port has been enabled, using the UP/DOWN arrows navigates through the calibration setup.
Here you can also select your calibration method.
TARGET
allows you to use the auto calibrate function and enter a known Unit Of Measure to calibrate pulses
to. When the known UOM is entered the start button can be used to count the necessary pulses. Once the
pulse have been counted press the CALC to auto update the MANUAL RATIO field
MANUAL RATIO
allows you to enter a known calibration factor. This could be a pulse per litre factor for a flow
meter to a known wheel circumference for speed & area (pulse/m). Scroll down & EDIT this field