3. Technical properties of the energisers OLLI 250B+, 180B
3.1. OLLI 180B indicator lights
The energiser has two indicator LED lights: The red pulse indicator and the
yellow low battery indicator
that is located below the fence LED. The red light
blinks in the rhythm of the fence pulse. The yellow LED indicates the battery
status as follows:
Battery LED display
Battery
charge
Indication/Action
No light
50
—100 %
Battery OK
Blinking with the
fence LED
Under 50 %
It would be a good idea to charge the
battery
Blinking with double
speed
Under 25 %
Charge the battery now
Continuous fast
blinking
Empty
The deep discharge protection is active.
Charge battery immediately to avoid
damage.
IMPORTANT:
If the red pulse LED lights for a longer time before starting
pulsing, the energiser may have an operation problem. Disconnect the
battery, wait for a moment and start the energiser again. If the situation
repeats, deliver the energiser to service.
3.1.2. Using the OLLI 180 B with Olli solar panel
IMPORTANT:
The full installation instruction is included the Olli solar panel
kit.
The 20 W Olli solar panel kit has a lead kit with battery clamps. Connect the
battery clamps of the energiser and the solar panel both to the poles of the
battery, the red marked connectors to the plus pole and the black marked
connectors to the minus pole.
The charging current flows now directly from the solar panel to the battery.
Disconnect the solar panel from the battery if the energiser is not being used for a
period of a week or more. If you discover that the battery has over heated due to
over charging, disconnect the solar panel from the battery and let the energiser
discharge the battery for a while before re-connecting the solar panel.
IMPORTANT:
If you want to check the battery status in solar panel use, you
need to disconnect the solar panel or do the check when the panel is not