USE AND MAINTENANCE MANUAL - SECTION 1
AERIAL PLATFORM ZP
– Rev. 05_2018
Page 1-5
•
Keep both feet firmly on the floor of the work platform. Do not place
ladders, boxes, steps, planks or similar items on the platform to increase
its range of action.
•
Do not use the extension unit to climb on or off the work platform.
•
Pay the utmost attention when entering or exiting the work platform.
Make sure the extending structure is lowered completely. Face the
machine when entering or exiting the work platform. Always maintain
"three contact points" with the machine, while making sure that both
hands and one foot or one hand and both feet are continuously in contact
with the machine when entering and exiting.
Electrocution hazard
Maintain a distance of at least 3 m between the machine parts and the
occupants with their tools and equipment, and an electric line or equipment
having an electric charge of up to 50,000 Volt. 0.3 m must be added for every
increment equal to or less than 30,000 Volt.
Voltage range
(from phase to phase)
Minimum safety operational
distance [m]
From 0 to 50 kV
3
From over 50 to 200 kV
5
From over 200 to 350 kV
6
From over 350 to 500 kV
8
From over 500 to 750 kV
11
From over 750 to 1000 kV
14
NOTE: such minimum safety operational distance is applied except in
cases where the company, local and government regulations are stricter.
Table 1-1: Minimum safety operational distance
Summary of Contents for ZP8
Page 84: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ZP Rev 05_2018 Page 9 7 ...
Page 86: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ZP Rev 05_2018 Page 9 9 ...
Page 88: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ZP Rev 05_2018 Page 9 11 ...
Page 90: ...NOTES ...
Page 91: ......