![Faraone PKS 1200E Use And Maintenance Instructions Download Page 44](http://html1.mh-extra.com/html/faraone/pks-1200e/pks-1200e_use-and-maintenance-instructions_3419222044.webp)
USE AND MAINTENANCE MANUAL - SECTION 4
AERIAL PLATFORM PKS 1200E-920-720 - Rev 02_2016
Page 4-9
1. Emergency STOP with removable key
2. Battery charge/operating hours display
3. Buzzer
4. Controls at base/controls on console selector
5. Work platform run/movement selector
6. Indicator LED
7. Cloche control
8. Right/left wheel rotation button
9. Dead man enabling control
General information
Before actuating the machine from the control console on the work platform,
it is necessary to satisfy the following conditions of the controls:
•
Ground control station
– The main power supply switch must be
switched on (plug inserted correctly).
•
Ground control station - The Emergency stop/switch-off button must
be in RESTORE position (POWER SUPPLY CONNECTED).
•
Work platform console - The control selector must be set at
"CONTROLS ON CONSOLE".
•
Platform console - The emergency stop/switch-off button must be in
RESTORE position (POWER SUPPLY CONNECTED).
Emergency STOP button with removable key
The emergency button located inside the control console of the work platform
is provided with a removable key to prevent the machine from being used by
unauthorised personnel. Press the button and remove the key to disconnect
general power.
Summary of Contents for PKS 1200E
Page 75: ...USE AND MAINTENANCE MANUAL SECTION 7 AERIAL PLATFORM PKS 1200E 920 720 Rev 02_2016 Page 7 8...
Page 77: ...USE AND MAINTENANCE MANUAL SECTION 7 AERIAL PLATFORM PKS 1200E 920 720 Rev 02_2016 Page 7 10...
Page 78: ...USE AND MAINTENANCE MANUAL SECTION 7 AERIAL PLATFORM PKS 1200E 920 720 Rev 02_2016 Page 7 11...
Page 85: ...USE AND MAINTENANCE MANUAL SECTION 7 AERIAL PLATFORM PKS 1200E 920 720 Rev 02_2016 Page 7 18...
Page 86: ...NOTES...
Page 87: ...Page left intentionally blank...