ENGLISH
ENGLISH
GB-33
GB-32
Note: The safety distance between the
hotplate and the cupboard above the
hotplate should be at least 760 mm.
A(mm)
B(mm)
C(mm)
D
E
760
50 mini
20 mini
Air intake
Air exit 5mm
9.2 Before installing the hob, make sure that
• The work surface is square and level, and
no structural members interfere with space
requirements.
• The work surface is made of a heat-resistant
material.
• If the hob is installed above an oven, the oven
has a built-in cooling fan.
• The installation will comply with all clearance
requirements and applicable standards and
regulations.
• A suitable isolating switch providing full
disconnection from the mains power supply
is incorporated in the permanent wiring,
mounted and positioned to comply with the
local wiring rules and regulations.
• The isolating switch must be of an approved
type and provide a 3 mm air gap contact
separation in all poles (or in all active [phase]
conductors if the local wiring rules allow for
this variation of the requirements).
• The isolating switch will be easily accessible to
the customer with the hob installed.
• You consult local building authorities and
by-laws if in doubt regarding installation.
• You use heat-resistant and easy-to-clean
finishes (such as ceramic tiles) for the wall
surfaces surrounding the hob.
9.3 After installing the hob, make sure that
• The power supply cable is not accessible
through cupboard doors or drawers.
• There is adequate flow of fresh air from outside
the cabinetry to the base of the hob.