Anti
-
F
*
controller in COOL, DRY or AUTO mode. It will operate in HEAT
mode (FAN mode for cool only units), with the internal fan
running with weak flow for 3 minute before stop, to remove the
moisture within the evaporator so as to prevent it from giving
off bad smell from mold.
*
This function is not set in the factory. You may set it or cancel it
any time you want as follows: With both the unit and the remote
controller OFF, point the remote controller at the unit and press
“Anti-F” button once, the buzzer will sound 5 times after 5 times,
indicating this function is set. Once set, this function will remain
valid except when the unit is power off or until it is canceled.
*
To cancel Anti-F:
1. Power off the unit.
2. With both the unit and the remote controller OFF, point the
remote controller at the unit and press this button once, the
buzzer will sound 3 times after 5 times, indicating this function
is canceled.
Note:
*
With Anti-F activated, it is advised not to turn ON the unit
again before it is fully OFF.
*
Anti-F function will be invalid when OFF timer is set.
The Anti-F functions when the unit is turned off with the remote
15
.