RAID Configuring
3-53
3.10.3 Hardware Monitor
To view the RAID subsystem controller’s hardware monitor information, move the
mouse cursor to the main menu and click the
Hardware Monitor
link. The
Hard-
ware Information screen appears.
The Hardware Monitor Information provides the temperature and voltage of the
internal RAID subsystem. All items are also unchangeable. The warning messages
will indicate through the LCD, LED and alarm buzzer.
Item
Controller Board Temperature
HDD Temperature
Power 12V
Power 5V
Power 3.3V
DDR Supply V2.5V
CPU Core V1.3V
DDR Termination Power +1.25V
Warning Condition
> 60 Celsius
> 55 Celsius
< 10.5V or > 13.5V
< 4.7V or > 5.4V
< 3.0V or > 3.6V
< 2.25V or > 2.75V
< 1.17V or > 1.43V
< 1.125V or > 1.375V
NOTE: When no disk drive is installed in the disk slot, the disk temperature
will show “—”. The disk temperature will also show “—” when “HDD SMART
Status Polling” is disabled in System Configuration.