Fantech PB110F Installation, Operation And Maintenance Manual Download Page 2

1. Before selecting mounting location for fan, consider the following: 

a) Mounting the fan as far as possible from the intake point will

assure quiet operation. A minimum of 8’ of insulated flexible duct
is recommended between exhaust grille and fan. 

b)  Place fan where it can be easily accessed for service.

2. Attach the mounting bracket to a support beam with wood screws

provided. Fan can be mounted at any point along the duct and at any
angle. Vertical mounting is recommended to reduce condensation in
the fan. For horizontally mounting, either wrap insulation around the
fan or drill a 

1

4

" hole in the bottom of the housing. Add NPT insert

and drain tube (purchased separately) for drainage of condensation. 

3. For PB Series fans, if bracket is used to mount fan, refer to illustration 1.

If suspending fan with hanger straps, refer to illustration 2.

4. Connect duct to inlet and outlet of fan using plastic ties or duct tape

(purchased separately). When using insulated flexible duct, the inner
vinyl core should be clamped or taped to the inlet and outlet and the
vapor barrier surrounding the insulation should be duct taped to the fan
housing.

Fantech recommends insulated flexible duct for all bathroom

exhaust applications.    

Please Note:

Steps 2 & 3 may be reversed.

2

Installing Fan and Bracket

Flexible Duct Installation Hints

Fantech strongly recommends the use of flexible insulated duct where
ducting passes through unconditioned space or where noise is a factor.

Check local code requirements before installing.

Failure to use insulated

flexible duct could result in excessive condensation buildup within the duct,
and undesirable sound levels within the room. 

A minimum of 8' of insulated flexible duct is recommended between 
the fan and any inlet grille. Duct should be stretched as tight and straight 
as possible. Failure to do so could result in dramatic loss of system 
performance. Connect flex duct to the fan with plastic zip ties or duct tape.
Connections should be airtight as possible for maximize performance.

Wiring Diagrams

Multiple Location Switching Wiring Diagram

Electrical Connection

1.

Remove the screws securing the terminal box cover located on the side
of the fan. All fan motor connections are pre-wired to an electrical
terminal strip. A 

3

8

" romex type cable restraint connector will be needed

to secure the wiring through the knockout on the side of the terminal box. 

2. Bring incoming electrical service through the romex connector and the

fan knockout. Be sure to place the connector nut over the wiring coming
into the terminal box. There are three open ports on the terminal strip.
Using a small regular screwdriver, tighten the neutral (white) wire of the
incoming supply under the open terminal strip port labeled "N". Tighten
the line (black) wire of the incoming supply under the open terminal strip
port labeled "L". Tighten the ground (green) wire of the incoming supply
under the open terminal strip port labeled with the Ground symbol.  If the
terminal strip is not labeled, follow the wiring diagram found on the inside
of the electrical cover.

3. Secure the romex connector. Secure the incoming supply with the romex

connector. Replace the fan terminal box cover. All fan motor and
capacitor connections have been pre-wired from the factory. No
additional fan wiring is necessary.

Troubleshooting

If fan fails to operate, please check the following:

1. Consult wiring diagrams (above) to ensure proper connection.

2. Check motor lead wiring, capacitor leads and incoming supply leads

to insure definite contact.

3. If possible, use a meter to test for continuity across the fan motor

leads. In order to do this, the capacitor must be disconnected (do
not test the capacitor - it will not meter continuity). If motor leads
show continuity, consult factory for a replacement capacitor.

Maintenance Instructions

Since fan bearings are sealed and provided with an internal lubricating
material, no additional lubrication is necessary.

With Motor Speed Controller

Without Motor Speed Controller

Illustration 1

Fan bracket should be installed, then fan mounted directly 

to bracket using sheet metal screws.

Models

• PB110 
• PB110F
• PB110H 
• PB190 

• PB270-2 
• PB270F-2 
• PB270H-2 
• PB270FV-2
• PB270HV-2

Models

• PB370-2

Illustration 2

Fans may be
suspended
without special
mounting
brackets.

Clamp Fastener

Duct Fan

Screws

Spiral duct

Vibration absorbing material

Mounting Bracket & Screw Locations for FG

Models

• PB100
• PB100F
• PB100H

Models

• PB190
• PB270-2
• PB270F-2 
• PB270H-2
• PB270FV-2
• PB270HV-2

Models

• PB370-2

Summary of Contents for PB110F

Page 1: ...tallations d When cutting or drilling into wall and ceiling do not damage electrical wiring and other hidden utilities e NEVER place a switch where it can be reached from a tub or shower f If this uni...

Page 2: ...box cover located on the side of the fan All fan motor connections are pre wired to an electrical terminal strip A 3 8 romex type cable restraint connector will be needed to secure the wiring through...

Page 3: ...to steps 4 and 5 3 Make Electrical Connections to the Ceiling Grille Housing Remove the electrical cover inside the steel housing using a screwdriver Connect power by following wiring diagram Figure 5...

Page 4: ...ithout notice any or all of its products features designs components and specifications to maintain their technological leadership position Item 412889 Rev Date 0810 United States 10048 Industrial Blv...

Page 5: ...vous coupez ou perforez un mur ou un plafond assurez vous de ne pas endommager les fils lectriques ou toute autre installation e NE JAMAIS placer un interrupteur pouvant tre atteint de la baignoire o...

Page 6: ...e la bo te de c blage sur le c t du ventilateur Tous les fils du moteur du ventilateur sont pr alablement c bl s une bande de branchement lectrique Un connecteur c ble encastr de type Romex 15 8 mm se...

Page 7: ...En utilisant un tournevis enlevez le couvercle lectrique l int rieur du bo tier en m tal Connectez le courant en suivant le diagramme de branchement Figure 5 et en suivant les codes lectriques locaux...

Page 8: ...tiques la conception les composantes et les sp cifications de ses produits afin de conserver sa position de leader en mati re de technologie Num ro d article 412889 Date de r vision 0810 United States...

Page 9: ...s cables el ctricos ni otros dispositivos de servicios ocultos e NUNCA instale un interruptor donde pueda ser alcanzado desde una tina o ducha f Si esta unidad se instala sobre una tina o ducha debe c...

Page 10: ...regleta el ctrica Se necesitar un conector de fijaci n de cables tipo romex de 3 8 para sujetar el cableado a trav s del agujero ciego provisto en el costado de la caja de conexiones 2 Pase la aliment...

Page 11: ...De lo contrario siga a los pasos 4 y 5 para completar la instalaci n de los modelos sin luces 3 Efect e las conexiones el ctricas a la caja de la rejilla de techo Con un destornillador retire la tapa...

Page 12: ...l derecho de modificar en cualquier momento y sin previo aviso todas y cada una de las caracter sticas dise os componentes y especificaciones de sus productos a fin de conservar su lugar de liderazgo...

Reviews: