Fantech PB110F Installation, Operation And Maintenance Manual Download Page 1

PB Series

IMPORTANT: PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

PREMIUM BATH FANS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

WARNINGS:

DO NOT CONNECT POWER SUPPLY until unit is completely installed. 
Make sure electrical service to the fan and light is locked in“OFF” position.

WARNING!

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS – 
OBSERVE THE FOLLOWING:

a.  Use this unit only in the manner intended by the manufacturer. If you have any questions, contact your 

manufacturer's representative.

b.  CAUTION:  Before installation, servicing or cleaning unit, switch power off at service panel and lock the service

disconnecting means to prevent power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device, such as tag, to the service panel.

c.  Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable

codes and standards. This unit is only for use in non-fire-rated installations.

d.  When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities.

e.  NEVER place a switch where it can be reached from a tub or shower.

f.  If this unit is installed over a tub or shower, it must be connected to a GFCI (Ground Fault Circuit Interrupter) –

protected branch circuit.

g.  The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit’s 

operation.  Follow the heating equipment manufacturer’s guidelines and safety standards such as those
published by the National Fire Protection association (NFPA), the American Society of Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE) and the local code authorities.

h.  Exhaust fans must always be vented to the outdoors.

CAUTION

: "For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Material and Vapors."

CAUTION:

BULB USED IN FLUORESCENT MODELS NOT DIMMABLE

CAUTION:

USE ONLY FANTECH (MODEL PBB14) FLUORESCENT BULBS AND 
PAR16/MR16 GU10 50W MAX. HALOGEN BULBS (FANTECH MODEL PBB50). 

Single Grille Units
4" Duct

PB110 
PB110F 
PB110H 

PB190
PB270-2
PB270F-2
PB270H-2 

PB270FV-2
PB270HV-2 
PB370-2

Single and Dual Grille Units 6" Duct

SEVEN-YEAR

WARRANTY

Summary of Contents for PB110F

Page 1: ...tallations d When cutting or drilling into wall and ceiling do not damage electrical wiring and other hidden utilities e NEVER place a switch where it can be reached from a tub or shower f If this uni...

Page 2: ...box cover located on the side of the fan All fan motor connections are pre wired to an electrical terminal strip A 3 8 romex type cable restraint connector will be needed to secure the wiring through...

Page 3: ...to steps 4 and 5 3 Make Electrical Connections to the Ceiling Grille Housing Remove the electrical cover inside the steel housing using a screwdriver Connect power by following wiring diagram Figure 5...

Page 4: ...ithout notice any or all of its products features designs components and specifications to maintain their technological leadership position Item 412889 Rev Date 0810 United States 10048 Industrial Blv...

Page 5: ...vous coupez ou perforez un mur ou un plafond assurez vous de ne pas endommager les fils lectriques ou toute autre installation e NE JAMAIS placer un interrupteur pouvant tre atteint de la baignoire o...

Page 6: ...e la bo te de c blage sur le c t du ventilateur Tous les fils du moteur du ventilateur sont pr alablement c bl s une bande de branchement lectrique Un connecteur c ble encastr de type Romex 15 8 mm se...

Page 7: ...En utilisant un tournevis enlevez le couvercle lectrique l int rieur du bo tier en m tal Connectez le courant en suivant le diagramme de branchement Figure 5 et en suivant les codes lectriques locaux...

Page 8: ...tiques la conception les composantes et les sp cifications de ses produits afin de conserver sa position de leader en mati re de technologie Num ro d article 412889 Date de r vision 0810 United States...

Page 9: ...s cables el ctricos ni otros dispositivos de servicios ocultos e NUNCA instale un interruptor donde pueda ser alcanzado desde una tina o ducha f Si esta unidad se instala sobre una tina o ducha debe c...

Page 10: ...regleta el ctrica Se necesitar un conector de fijaci n de cables tipo romex de 3 8 para sujetar el cableado a trav s del agujero ciego provisto en el costado de la caja de conexiones 2 Pase la aliment...

Page 11: ...De lo contrario siga a los pasos 4 y 5 para completar la instalaci n de los modelos sin luces 3 Efect e las conexiones el ctricas a la caja de la rejilla de techo Con un destornillador retire la tapa...

Page 12: ...l derecho de modificar en cualquier momento y sin previo aviso todas y cada una de las caracter sticas dise os componentes y especificaciones de sus productos a fin de conservar su lugar de liderazgo...

Reviews: