Shut Down Mode

Pressing the power button after the first minute of operation will initiate a shut-down mode. This mode 
will last 15 minutes and will maintain the operation of the fan and purge pump to insure all water is 
removed from the unit prior to moving or storing. Pressing the power button at any time during the shut 
down mode will immediately shut down the unit and bypass the remainder of the shutdown mode. The 
unit must be purged by pressing the purge button if bypassing the shutdown mode to avoid water 
overflow.

The display will change during shutdown mode to a countdown timer that will indicate the 
time remaining before the unit shuts completely off. 

Maintenance

Air Filter (Fig. 7)

The air filter should be checked regularly. Operating the dehu-

midifier with a clogged filter will reduce efficiency. The filter can be

vacuum cleaned to remove dust. To access the filter media, slide

the filter frame up until it clears the dehumidifier cabinet. Remove

the filter media from behind the frame and vacuum. Reverse pro-

cedure to re-install the filter and frame into the dehumidifier.

Storage

Freezing temperatures and biological growth must be considered

before  storing  the  dehumidifier.  The  dehumidifier  should  be

flushed with a biofungicide before storing. When storing the unit,

ensure  that  water  has  been  removed  from  the  reservoir  and

hose. This will prevent damage caused by freezing temperatures

and to prevent biological growth. Use the pump purge button to

remove water and biofungicide chemicals from the dehumidifier.

Stacking (Fig.9)

The dehumidifiers can be stacked on top of each other. The

wheels from the upper unit must be resting in the cradle of

the lower unit. 

DO NOT STACK MORE THAN TWO HIGH. 

External Cleaning

Use  a  non-flammable  mild,  non-abrasive  soap  and  clean

water solution to clean the dehumidifier. Wipe dry.

Internal Cleaning

Disconnect dehumidifier from power supply. 

Light cleaning:

Remove the air filter and spray evaporator

coil  with  water.Remove  the  two  upper  screws  from  the  front

hood. 

Heavy cleaning:

Remove two upper screws from front hood.

Open  hood.  Spray  water  at  coils.  Close  hood  and  replace

screws. (Fig. 8)

Fig. 7

Fig. 8

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.

WARNING

Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,

fire, or electrical shock.

Venting / Ducting (Fig. 6)

Twin  rear  outlets  can  accommo-

date two individual 5” ducts or one

10”  lay  flat  duct  to  be  attached.

This allows for warm dry air to be

directed into different areas.

Fig. 6

Cleaning

Fig. 9

Service

A qualified refrigeration technician must service all refriger-

ant leaks. 
WARNING: The dehumidifier uses a high pressure refrigerant

system and high voltage circuitry which could present a health

hazard resulting in death, serious bodily injury, and/or property

damage. Only qualified service people should service this unit.

CAUTION:

Do not operate unit without the front hood secured in

place.
The serial data plate is located on the underside of the dehumid-

ifier. For service information contact 1-800-565-3548.

(2)

Figure 11

Figure 12

Functions

Loss of Power Recovery Function

In case of a loss of power, the last run state (ON  or  OFF) will be maintained when the power is 
restored.

Pump Purge Function

In normal operation, the pump will automatically empty the reservoir. Pressing the purge button 
(figure 9)  runs the pump for 1 minute allowing manual emptying of the reservoir. The pump purge 
will function in all modes as long as the unit is plugged in.  

Hour Meter Display

The cumulative hours will be displayed during normal operation. If the unit is off (even unplugged) 
pressing the hour button (figure 10) will also display the accumulative hours briefly.

Venting / Ducting

Twin rear outlets (figure 11) can accommodate two individual 5” ducts or one 10” lay flat duct to be 
attached. This allows for warm dry air to be directed into different areas.

Maintenance

Air Filter

The air filter should be checked regularly. Operating the dehumidifier with a clogged filter will reduce 
efficiency. To access the filter, slide the filter frame up until it clears the dehumidifier cabinet 
(figure 12). Reverse procedure to re-install the filter into the dehumidifier. Metal filters should be 
washed with soap and water, and paper filters should be replaced.

Paper filter size is a nominal 12" x 12" x 1"

Operating the unit without the filter in place will cause reduced efficiency due to dirty coils and 
increase the frequency of internal coil cleaning.

Stacking

The dehumidifiers can be stacked on top of each other (figure 13). The wheels from the upper unit 
must be resting in the cradle of the lower unit. DO NOT STACK MORE THAN TWO HIGH.

Battery Replacement

Disconnect power supply before replacing battery.
Failure to follow these instructions can result in death, fire, or electrical shock

Disconnect dehumidifier from power supply. The hour meter uses a battery backup for display when the 
dehumidifier is unplugged and the hour button is depressed. To change the battery, it is necessary to remove 
the four (4) screws from the control panel. Disconnect the old battery and replace with new battery. 
Replace control panel and screws. Do not overtighten screws. 

Figure 9

Figure 10

Maintenance

Air Filter (Fig. 7)

The air filter should be checked regularly. Operating the dehu-

midifier with a clogged filter will reduce efficiency. The filter can be

vacuum cleaned to remove dust. To access the filter media, slide

the filter frame up until it clears the dehumidifier cabinet. Remove

the filter media from behind the frame and vacuum. Reverse pro-

cedure to re-install the filter and frame into the dehumidifier.

Storage

Freezing temperatures and biological growth must be considered

before  storing  the  dehumidifier.  The  dehumidifier  should  be

flushed with a biofungicide before storing. When storing the unit,

ensure  that  water  has  been  removed  from  the  reservoir  and

hose. This will prevent damage caused by freezing temperatures

and to prevent biological growth. Use the pump purge button to

remove water and biofungicide chemicals from the dehumidifier.

Stacking (Fig.9)

The dehumidifiers can be stacked on top of each other. The

wheels from the upper unit must be resting in the cradle of

the lower unit. 

DO NOT STACK MORE THAN TWO HIGH. 

External Cleaning

Use  a  non-flammable  mild,  non-abrasive  soap  and  clean

water solution to clean the dehumidifier. Wipe dry.

Internal Cleaning

Disconnect dehumidifier from power supply. 

Light cleaning:

Remove the air filter and spray evaporator

coil  with  water.Remove  the  two  upper  screws  from  the  front

hood. 

Heavy cleaning:

Remove two upper screws from front hood.

Open  hood.  Spray  water  at  coils.  Close  hood  and  replace

screws. (Fig. 8)

Fig. 7

Fig. 8

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.

WARNING

Disconnect power supply before cleaning.
Failure to follow these instructions can result in death,

fire, or electrical shock.

Venting / Ducting (Fig. 6)

Twin  rear  outlets  can  accommo-

date two individual 5” ducts or one

10”  lay  flat  duct  to  be  attached.

This allows for warm dry air to be

directed into different areas.

Fig. 6

Cleaning

Fig. 9

Service

A qualified refrigeration technician must service all refriger-

ant leaks. 
WARNING: The dehumidifier uses a high pressure refrigerant

system and high voltage circuitry which could present a health

hazard resulting in death, serious bodily injury, and/or property

damage. Only qualified service people should service this unit.

CAUTION:

Do not operate unit without the front hood secured in

place.
The serial data plate is located on the underside of the dehumid-

ifier. For service information contact 1-800-565-3548.

(2)

Figure 13

Summary of Contents for EPD Series

Page 1: ...che NB E4S 3M5 Tel 800 565 3548 Fax 877 747 8116 EPD Series Industrial Dehumidifier Deshumidificador industrial Industrial Dehumidifier Déshumidificateur industriel Deshumidificador industrial Operating Instructions Guide d utilisation Instrucciones de uso Read and Save These Instructions Lisez et conservez ces instructions Lea y guarde estas instrucciones 1 3 5 405037 Fantech Ltd 1 800 565 3548 E...

Page 2: ...cte a un contacto de pared de conexión a tierra de 3 terminales No quite la terminal de conexión a tierra No use un adaptador No use un cable elétrico de extensión No seguir estas instrucciones puede ocasional la muerte incendio o choque eléctrico ADVERTENCIA El deshumidificador utiliza un sistema de líquido refriger ante de alta presión y un circuito eléctrico de alto voltaje que podrían resultar...

Page 3: ...cted areas Route condensate hose into a drain or a very large container OFF Mode The unit is OFF but plugged in a 120V AC power source The back light of the display panel in on See figure 1 Start up Mode The dehumidifier is turned on by pressing the power button figure 2 When the dehumidifier is started the display will briefly show the software version and the unit status figure 3 followed by a 5...

Page 4: ...humidifier cabinet figure 12 Reverse procedure to re install the filter into the dehumidifier Metal filters should be washed with soap and water and paper filters should be replaced Paper filter size is a nominal 12 x 12 x 1 Operating the unit without the filter in place will cause reduced efficiency due to dirty coils and increase the frequency of internal coil cleaning Stacking The dehumidifiers...

Reviews: