background image

Summary of Contents for Quiet Comfort II 758.144530

Page 1: ...I II I I _Save This Manual for Future Reference owner s manual Model No 758 144530 13 Gallon t qenmope R II _ _ALL TION Parts List J Sears Roebuck and Co Hoffman Estates IL 60179 U S A Part No SP5949 Printed in U S A ...

Page 2: ... the electric cord under rugs near heat registers radiators stoves or heaters 3 Always unplug the humidifier before moving it removing the housing sec tion before cleaning or whenever the humidifier is not in service J 10 Table of Contents Warranty Information 2 General Safety Instructions 2 To Save a Service Call 2 Know Your Humidifier 3 Humidifier Operations 4 Location Instructions 4 5 Electrica...

Page 3: ...or Clarity Description 758 144530 Gallon Output 24 Hrs Capacity Tanks or Bottles Sq Ft Coverage Run Time Fan Speeds Filters Fill Light Water Level Indicator Auto Humidistat Auto Shut Off Controls Operating Light U L Listed AHAM Certified Volts Hertz Amps Watts 13 2 Bottles 3000 48 Hours Variable 4 Yes Yes Yes Yes Slide Adj Yes Yes Yes 120 A C 60 2 88 165 ...

Page 4: ...Sears store Your new Sears Kenmore humidifier is completely assembled for you to use Remove the packaging material from inside your humidifier and follow the I lille II I I IIII I I II IIIIIIIIIIIII instructions of this owner s manual for proper usage The packaging material is located under the fan assembly Remove the packaging material and discard Location Instructions WARNING For your own safety...

Page 5: ...ok Up Locate nearest 120V A C wall socket in the location desired preferably on inside wail Plug in the electrical cord WARNING To avoid fire or shock hazard humidifier should be plugged into a 120V A C outlet Do not use extension cords j iiiiiiiiiiiiiiii iiiiiiiii iii i iiiil llllllllllllllll ii Water Fill WARNING To avoid shock always unplug humidifier before filling cleaning or servicing WARNIN...

Page 6: ...alLthe fill cap by twisting clockwise Hand tighten only Check for possible leaks by performing the following 1 Grasp bottle handle and hold bottle upright over sink 2 Press up on reservoir cap plunger about one second to let out a little water 3 Release the plunger 4 Listen for air bubbles Look for leaks around fill cap 5 If you hear air bubbles or see leaks retighten cap and repeat steps 1 4 Wipe...

Page 7: ...or unplugged Fill Light When the unit has a small amount of water left in it the fill light will come on and the unit will automatically shut off Speed Control The unit is adjusted from low to high with a variable speed control The higher the air flow speed the more water is evaporated and released into the air Low speed is the quietest and is pro vided for conditions that may not require as high ...

Page 8: ...ed level Allow 24 hours for humidifier to adjust If humidity level in home is sufficient the humidifier will only operate with Humidity Control set on maximum IMPORTANT Water damage may result if condensation starts to form on windows or wails Humidity Control setting should be lowered until condensation no longer forms III IIIIIII I IIIIIIIIIIIII I Step 5 If humidifier stops running the humidity ...

Page 9: ...r to an area where floor coverings are not suscep tible to water damage i e kitchen or bath areas 2 To remove parts Remove the fan assembly by opening the pivoting lid Grasp the fan assem bly front center and rear center Lift off and set aside on a clean flat surface The filter assemblies are now accessi ble Remove water bottles and set aside 3 Lift filter housings out of cabinet and place where y...

Page 10: ...a front and back orientation To posi tion the filter housings correctly in the cabinet make sure the two indents in the cylinder section of the top covers are positioned towards the center of the cabinet Also be sure that the spring finger portions of filter housings are towards front of cabinet Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humi...

Page 11: ...hich contains the motors and fans and set aside See Repair Parts list b Remove the water bottles from the cab inet and remove the filter housings see Repair Parts list for identification c Empty Cabinet d The cabinet should be empty and the water reservoir is ready for cleaning The water reservoir consists of the lower areas of the humidifier cabi net e Proceed to Bi Weekty Maintenance or End of S...

Page 12: ...2 Empty water reservoir after 20 minutes Rinse with water until bleach smell is gone Allow unit to dry out completely 3 Water bottles should be cleaned in same manner End of Season Maintenance 1 Follow bi weekly maintenance instruc tions at end of humidification season or when humidifier will not be used for at least one week or more 2 Remove and throw away filters 3 Let humidifier dry completely ...

Page 13: ...r bottles This is normai _ small amount of water remains in the cabinet Allow unit to continue opera tion check Caps to ensure tightness Check for leak in water bottles Are gaskets for caps in place see repair parts list Change to a fresh new filter Check orientation of bottle Reposition so that reservoir cap plunger is depressed by post in bottom of cabinet o Raise humidistat setting if possible ...

Page 14: ... __ 40 38A ...

Page 15: ...ludes Keys 20 21_ Gasket Fill Cap Liner Cap Bottle Right Bottle Left Seal Valve Siandard Hardware Item May be purchased locally Key No Model 758 144530 0 25 821421 1 26 27 28 29 30 823726 31 STD601 819026 819027 822419 2 823710 2 32 822120 33 823849 34 9 14911 35 823977 36 823715 37 823735 38 822405 1 38a 822405 2 39 822406 1 40 816069 2 t 41 823714 42 824118 SP5949 Description Ring o Spring Valve...

Page 16: ...8 1 222 Zmmll man For information on purchasing a Sears Maintenance Agreement or to inquire about an existing Agreement Call 9 am 5 pro Monday Saturday 1 800 827 6655 SEARS Atnerica s Repair pectafists The model number will be found on the Humidifier identification label When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part De...

Reviews: