2. PRODUCT DESCRIPTION & SPECIFICATIONS

PRODUCT DESCRIPTION

Industrial electric space/fan heater.

SPECIFICATIONS

MODEL

HES2.4

Heat Output

2400 W

6,824 BTU

Air Flow (L/s)

57

Control settings

1 x Fan setting

2 x Heat settings 

Settings (W)

30/1200/2400

Voltage (V/Hz)

240V/50

Self-Resetting 

thermostat

70’C

Current Rating (A)

10

Fuse Rating

16A

Net Weight (kg)

4.9

Dimensions (mm)

325(L)*250(W)*375(H)

SAFETY DEVICES

This heater has 3 protection devices:

•  Tilt Switch

 - this will automatically turn the heater off if it is not in the appropriate 

operating position, fallen over on its front or side.

•  Self-Resetting Thermostat

 - this will automatically disconnect the power to the 

heater at a pre-set overheat temperature (70’C). After cooling down it will reset & 

turn on again. If this occurs, investigate what is causing the heater to overheat.

•  Thermal fuse

 - this disconnects the heater permanently in case of overheating. (It 

is non resettable).

Summary of Contents for HES2.4

Page 1: ...ng ventilation extraction INSTRUCTION MANUAL MODEL HES2 4 ELECTRIC SPACE HEATER TO PREVENT SERIOUS INJURY READ UNDERSTAND ALL WARNINGS INSTRUCTIONS BEFORE USE PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS FOR INDUSTRIAL USE ONLY ...

Page 2: ... we make no warranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion and risk of the user Disposal Guidelines Do not dispose of this product with general household waste This product must be disposed according...

Page 3: ...R OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS NOT FOR DOMESTIC OR RECREATIONAL VEHICLE USE THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE IS CONNECTED MUST COMPLY WITH LOCAL REGULATION...

Page 4: ...nsions mm 325 L 250 W 375 H SAFETY DEVICES This heater has 3 protection devices Tilt Switch this will automatically turn the heater off if it is not in the appropriate operating position fallen over on its front or side Self Resetting Thermostat this will automatically disconnect the power to the heater at a pre set overheat temperature 70 C After cooling down it will reset turn on again If this o...

Page 5: ...source Set the thermostat knob to the MAX let the heater operate on full power The fan heater will switch on when the heating selector is set to one of the power settings Once the room reaches the required temperature the heating element will cut out the fan will continue Once the ambient temperature decreases the heating element will cut back in The fan heater now starts and stops automatically a...

Page 6: ...nner parts Do not spray water into the heater Never use solvents gasoline toluene and similar aggressive chemicals to clean the heater Regularly wipe the enclosure using a soft sponge or cloth For very dirty parts use a sponge wetted with lukewarm water and a mild detergent then dry using a clean cloth Regularly inspect the power cable if worn cracked or damaged have it replaced by a qualified per...

Page 7: ...5 WIRING DIAGRAM ...

Page 8: ...6 PARTS BREAKDOWN ...

Page 9: ...er doesn t heat up only the fan The switch was not put on heat setting Turn switch to heat setting Thermostat in operation ambient temperature acheived or overheating Turn the thermostat know listen for a click If there is no click the thermostat is not damaged the heater will automaticaly switch on when the heater has cooled down The Self Resetting thermostat in operation overheating Turn the hea...

Page 10: ... cannot be excluded under the Australian Consumer Law You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Exclusions This warranty does not cover Any defects caused...