How to Operate Your Ceiling Fan

1.

Restore electrical power to the outlet box by turning

the electricity on at the main fuse box (Figure 1).

Figure 4

Figure 3

4.

If airflow is desired in the opposite direction, turn

the fan off and wait for the blades to stop turning.

Slide the coupling cover up to expose the reverse

switch. Then slide the reverse switch on top  of

motor assembly to the opposite position and turn

fan on again (Figure 4).

Check to see that all connections are tight, including

ground, and that no bare wire is visible at the wire

connectors, except for the ground wire. Do not

operate fan until the blades are in place. Noise and

fan damage could result.

WARNING

Reverse Switch Information

Season

Rotation Direction Switch Position

Summer

Counter-Clockwise

Left

Winter

Clockwise

Right

MAIN FUSE BOX

Figure 1

Reverse

Switch

Upper

Housing

2. 

LEARN MODE PROCESS: (

Figure 2)

Control and receiver have been factory programmed. 

If replacing the transmitter or receiver, the learn mode 

process will need to be used. 

1. 

After installing the unit and restoring power to your fan, 

open the battery cover (with batteries, DC1.5V/AAA 

4pcs, installed) and press and hold the ”LEARNING 

BUTTON” 1~3seconds with a ball-point pen or similar 

object. FAN will turn off and then turn to medium speed 

and light on, which indicates that the learning process 

has completed.      

2. 

IMPORTANT:  You must press the “LEARNING 

BUTTON” within 60 seconds of restoring power to the 

fan. Remote does not need to be re-learned when 

replacing the battery.   

Please note, the remote can learn multiple receivers.  

4. 

If light kit has CFL bulbs, please slide the “light dimmer 

function select switch” to on/off position. If installed 

incandescent light bulbs onto ceiling fan, please slide 

the “light dimmer function select switch” to dimmer 

position.  

3. 

3. 

REMOTE FUNCTIONS: (

Figure 3)

: If light is off, touch and release immediately and light 

will turn on. After 3 minutes, light will turn off.

: Touch and release immediately to turn fan on or off

: Touch and release immediately to turn change fan 

speeds low/medium/high

: Touch to select run time desired—from 1 to 12 hours. 

Fan will turn off after selected time duration.

: Touch and release immediately to turn light on or off 

  (CFL) Touch and release this key to brighten light to 

  the desired level (Incandescent)

: If light is on, touch and release immediately and light 

will turn off after 3 minutes

Figure 2

Install Remote Control 

Wall Mount Holder 

with two screws.

AAA

AAA

AAA

AAA

LEARNING

BUTTON

LIGHT DIMMER FUNCTION

        SELECT SWITCH

ON/OFF

DIMMER

Summary of Contents for Multimax FP8008CH1

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP8008CH1 Ceiling Fan Net Weight 20 5 lbs 9 3 kgs The Multimax...

Page 2: ...fails due to a defect in materials or workmanship during the lifetime of the original purchaser Fanimation will provide the replacement part free of charge when the defective fan is returned to our na...

Page 3: ...tion hereby disclaims any and all implied warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law Some states do not allow...

Page 4: ...ardware bags Four wire connectors Phillips screwdriver 4 Balance Kit Nine 1 4 steel washer Nine 1 4 20x1 2 screw w spring washer WARNING Do not install or use fan if any part is damaged or missing Thi...

Page 5: ...lar savings could be realized with this simple step Electrical and Structural Requirements If your fan is to replace an existing light fixture turn electricity off at the main fuse box at this time an...

Page 6: ...wires through the downrod Figure 3 Black Blue and White Leads DOWNROD DOWNROD 4 Position downrod support and align the clevis pin holes in both parts Install the clevis pin and secure with the hairpi...

Page 7: ...through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight...

Page 8: ...re 1 NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING Failure to seat tab in groove could cause damage...

Page 9: ...ng wire connector supplied Lastly connect blue wire from receiver to the blue fan light wire using wire connector supplied Position all connected wires and receiver antenna to allow installation of ce...

Page 10: ...Fully assemble and tighten second shoulder screw that was previously removed Figure 1 How to Install Your Canopy Housing To avoid possible fire or shock make sure that the electrical wires are comple...

Page 11: ...ousing by push and snap in Figure 2A Lower Housing Lower Housing Motor Assembly 2 PIN Connector Socket Plate 2 PIN Connector Socket Plate Assembly Socket Plate Assembly Figure 4 4 Remove one of the th...

Page 12: ...d Light Kit cont d Figure 5 5 Insert light bulbs into sockets Figure 5 Socket Plate Socket Plate Bulb Glass Figure 6 6 Assemble the glass to the socket plate assembly by twisting in a clockwise direct...

Page 13: ...LEARNING BUTTON 1 3seconds with a ball point pen or similar object FAN will turn off and then turn to medium speed and light on which indicates that the learning process has completed 2 IMPORTANT You...

Page 14: ...are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the finish and create the possibility of electrical sho...

Page 15: ...are not recommended choose an alternative control method 6 Tighten screws securely 7 Tighten set screw securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blad...

Page 16: ...ly w Screws 2 3 4 Canopy Screw Cover Assembly 5 6 7 8 9 10 11 12 13 15 HDWFP8008CH Downrod Hanger Ball Assembly Canopy Lower Housing Assembly Decorative Lower Housing Cover Fan Motor Assembly Bag Asse...

Page 17: ...17 NOTE The illustration shown is not to scale or its actual configurations may vary The Multimax FP8008CH1 Exploded View 1 2 3 13 14 4 12 6 7 8 9 10 11 15 5...

Page 18: ...Copyright 2012 2012 06 V 01 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Fanimation Visit Our Website www fanimation com...

Page 19: ...MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Tenga en cuenta todas las advertencias que se muestran Modelo N FP8008CH1 The Multimax Ventilador de techo Peso neto 20 5 lb 9 3 kg...

Page 20: ...ido en la Parte 15 de la Normativa FCC Su funcionamiento est sujeto a las dos condiciones siguientes 1 Este equipo no causar interferencias perjudiciales y 2 este equipo tolerar cualquier interferenci...

Page 21: ...tion niega todas las garant as impl citas que incluyen entre otras la comerciabilidad y la aptitud para determinado fin hasta donde la ley lo permita Algunos estados no permiten limitaciones sobre las...

Page 22: ...ramientas necesarias para el ensamblaje ADVERTENCIA Antes de ensamblar el ventilador de techo consulte la secci nsobreelm todocorrectodeinstalaci nel ctricadel ventilador p gina 18 Si siente que no po...

Page 23: ...l ventilador de techo a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que obliga al aire c lido que se acumula cerca del techo a bajar al espacio o...

Page 24: ...tuercas de seguridad en el soporte de la varilla interior Figura 4 Soporte de la varilla NEGRO AZUL Y BLANCO LLEVA Ranura de la bola colgante Pasador Tornillo de fijaci n Tornillo de fijaci n Y tuerca...

Page 25: ...os la la cubierta para el tornillo y el capuch n y Capuch n de techo Figura 7 Capuch n de techo Capuch n de techo la cubierta del tornillo de la base Pasador Tornillo de fijaci n Bola para colgar Sopo...

Page 26: ...entilador Figura 1 NOTA Si no est seguro de si la caja de distribuci n el ctrica tiene conexi n a tierra pida asesoramiento a un electricista autorizado ya que la conexi n a tierra es fundamental para...

Page 27: ...nexi n a tierra pida asesoramiento a un electricista autorizado ya que la conexi n a tierra es fundamental para un funcionamiento seguro ADVERTENCIA Para evitar posibles descargas el ctricas aseg rese...

Page 28: ...e reborde que antes hab a retirado y aj stelo Figura 1 Para evitar posibles incendios o descargas el ctricas aseg rese de que los cables el ctricos se encuentren completamente adentro de la cubierta d...

Page 29: ...lavijas Unidad de la placa de conexi n Inferior de la carcasa Inferior de la carcasa Inferior de la carcasa Unidad del motor del ventilador Inferior de la carcasa Cubierta decorativa Placa del kit de...

Page 30: ...ra 1 C mo utilizar su ventilador de techo 1 Restaure la fuente de alimentaci n de la toma de corriente enciendo la electricidad del fusible principal Figura 1 Compruebe que todas las conexiones realiz...

Page 31: ...ilar El ventilador se apagar y se volver a encender a velocidad media y con las luces encendidas lo que indicar que se ha completado el proceso de aprendizaje IMPORTANTE Debe pulsar el bot n LEARNING...

Page 32: ...antenimiento 1 El nico mantenimiento necesario para el ventilador de techo es una limpieza peri dica Al llevar a cabo la limpieza use s lo un cepillo suave o un pa o sin pelusas para evitar rayar el a...

Page 33: ...el suministro principal de electricidad est desconectado 5 Algunos motores de ventilador son sensibles a las se ales de los controles de velocidad de estado s lido variables Los controles de estado s...

Page 34: ...S DE ACABADO consulte el n mero de modelo del ventilador que se encuentra en el soporte de barral C mo hacer un pedido de piezas Al hacer un pedido de piezas de repuesto proporcione siempre la siguien...

Page 35: ...35 The Multimax FP8008CH1 Despiece 1 2 3 13 14 4 12 6 7 8 9 10 11 15 5 NOTA...

Page 36: ...ght 2012 2012 06 V 01 10983 Bennett Parkway Zionsville IN 46077 Llame sin cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fanimati...

Reviews: