Chapter 7 Parameter Setting
56
(The following is typical of the "T" in F2000 series CNC system)
Set Arc
:
set the arc while cutting, the range of value is 50.00-300.00
。
Unit: V
Arc Protection Value: When actual arc value
≥
(arc value setting + protection
value over arc), the system will give an alarm of breaking arc and stop cutting, the
range of the value is 5.00-100.00. Unit: V
。
Notice:
actual arc value is less than 30 V, system will also give the alarm of breaking
arc. This 30 V is fixed value and not modified.
THC Sensitivity: This is sensitivity reflected by THC motor. It turns larger, reflection
of THC motor turns more sensitive, but could not exceed the range
,
otherwise in the
process of motor turning high, it occurs wave phenomenon, it is normally set as
30-50
,
the range of which is 0.00-100.00
。
Unit: %. In the actual using, according to
the cutting speed and inertia of lifting, it will stop adjusting motor until the motor can
not shake and reach the level of turning high quickly.
Set Arc Manual Adjustment of Step: press F6 and F7 in auto interface, reduce or
increase the stride of setting arc, the range of value is 0.10-10.00. Unit: V
。
Fast Location Time
:
This is the time of full speed decline in the step of location
check decline, the range of which is more than or equal to 0.00, Unit: s.
Notice: Fast position time cannot be more than position check time.
7.4 Powder Parameters
As the figure 7.5 shows, it is powder parameters of system about the powder paint
line.
Summary of Contents for F2100B/T