23
Once your ceiling fan is installed in the hanger bracket, slide the receiver into the hanger bracket (above the
hanger ball).
10. INSTALL THE RECEIVER IN THE CEILING HANGER BRACKET
WARNING : Before proceeding to the electrical connections, carefully read the safety instructions in
this manual. Before any electrical connections, switch off all power and restart only when the instal-
lation is completed. Electrical connections must be made in accordance with current regulations and
by a qualified electrician.
11. ELECTRICAL CONNECTIONS
Once the receiver is installed in the hanger bracket, make the electrical connections below.
(See diagram on next page)
1/ CONNECTIONS FROM CEILING FAN TO RECEIVER
- Connect the connector of the ceiling fan (3 wires : grey / blue / black) to the receiver.
2/ CONNECTIONS FROM RECEIVER TO HANGER BRACKET
- Connect the connector of the hanger bracket (2 wires : brown or black / blue) to the receiver.
The brown or black wire corresponds to the phase (Line), the blue wire corresponds to the neutral.
3/ CONNECTIONS FROM HANGER BRACKET TO AC CEILING POWER
By using the connecting terminals provided on the hanger bracket :
- Connect the phase of the ceiling to the phase of the hanger bracket in the domino L (LINE : black or brown
wire of the hanger bracket).
- Connect the neutral of the ceiling with the neutral of the hanger bracket in the domino N (NEUTRAL : blue
wire of the hanger bracket).
Check that all electrical connections have been correctly made and that the receiver and the wires are prop
-
erly stored in the hanger bracket.