Clean the upper filter screen frame 

1

Unscrew one screw fixed by EVA filter net and back shell with screwdriver, and take out EVA filter net.                                                                                               

2

Put the EVA filter screen into warm water with neutral detergent (about 40

 / 104

) and dry it in the 

shade after rinsing clean. 

 

VIII. Unit Storage:

 

i. 

Unscrew the drainage cover, unplug the water plug, and discharge the water in the water pan into other 
water containers or directly tilt the body to discharge the water into other containers. 

ii. 

Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe 
becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing. 

iii. 

Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install 
the water plug and the drainage cover.   

iv. 

Remove the exhaust pipe and keep it properly. 

v. 

Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it out of the reach 
of children, and take dust control measures. 

vi. 

Remove batteries of the remote control and keep them properly. 

Note:

 ensure that the body is placed in a dry place and keep all machine components properly.

 

 

1. Information on servicing

 

1) Checks to the area   
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to 
ensure  that  the  risk  of  ignition  is  minimized.  For  repair  to  the  refrigerating  system,  the  following 
precautions shall be complied with prior to conducting work on the system.   
2) Work procedure   
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or 
vapour being present while the work is being performed.   
3) General work area   
All maintenance staff and others working in the local area shall be instructed on the nature of work being 
carried  out.  Work  in  confined  spaces  shall  be  avoided.  The  area  around  the  workspace  shall  be 
sectioned off. Ensure that the conditions within the area have been made safe by control of flammable 

Summary of Contents for PAH-1218

Page 1: ...LOCAL AIR CONDITIONER PAH 1218 Instructions Manual Read and save these instructions ...

Page 2: ...n 6 V Installation and adjustment 7 VI Drainage Instructions 9 VII Maintenance 10 VIII Out of season save 10 IX Troubleshooting 11 X Addendum 11 Please read these instructions before use and repair The drawings provided in this manual may not be the same as the physical objects Please refer to the physical objects ...

Page 3: ...ce and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants 12 All working procedure that affects safety means shall only be carried by competent persons Notes The air conditioning is only suitable for indoor use and is not suitable for other applications Follow local grid interconnection ...

Page 4: ...eaning and maintenance shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The appliance shall be installed in accordance with national wiring regulations Do not operate your air conditioner in a wet room such as a bathroom or laundry room Transportation m...

Page 5: ...unction Protection function of automatically restarting the compressor after three minutes a variety of other protection functions Max operation temperature for the air conditioner Cooling 35 24 heating 20 12 Temperature operation range 7 35 2 Components ...

Page 6: ...case of power on press the key to turn off the machine in the case of power off press the key to turn on the machine 3 Mode Selection Key In the case of power on press the key to switch between cooling dehumidification fan heating single cold with no such function cooling mode 4 Up Key and Down Key press the two keys to change the set temperature or timer set value Exhaust Pipe Assembly Window Sea...

Page 7: ...d speed operation In dehumidification mode pressing the key is invalid and the fan will forcibly choose low wind speed operation 6 Timer Key In the case of power on press the key to set turn OFF timer in the case of power off press the key to set turn ON timer Press the key when the timer symbol flashes press up and down key to select the required timer value Timer values can be set within 1 24 ho...

Page 8: ...o normal operation 3 2 Overflow Protection Function When water in the water pan exceeds the warning level the machine will automatically sound an alarm and the FULL indicator light will flash At this point you need to move the drainage pipe connecting the machine or the water outlet to sewer or other drainage area to empty the water details see Drainage Instructions at the end of this chapter Afte...

Page 9: ...d in horizontal and vertical direction 2 Pull various components of the window sealing plate assembly open adjust their opening distance to bring both ends of the assembly into contact with the window frame and fix various components of the assembly 1 2 Install the window sealing plate assembly Notes 1 the flat end of the exhaust pipe joints must be snapped into place 2 The pipe cannot be distorte...

Page 10: ...ice The length of the exhaust hose shall be 280 1 500mm and this length is based on the specifications of the air conditioning Do not use extension tubes or replace it with other different hoses or this may cause a malfunction Exhaust host must be not blocked otherwise it may cause overheating VI Drainage Instructions This machine has two drainage methods manual drainage and continuous drainage 1 ...

Page 11: ...e water plug and tighten the drainage cover 2 Continuous drainage Optional only applicable to dehumidifying mode as shown in figure 1 Unscrew the drainage cover and unplug the water plug 2 Set the drainage pipe into the water outlet 3 Connect the drainage pipe to the bucket VII Maintenance Cleaning before cleaning and maintenance turn off the machine and unplug the plug 1 Clean the surface Clean w...

Page 12: ...ioning with a plastic bag Put the air conditioning in a dry place keep it out of the reach of children and take dust control measures vi Remove batteries of the remote control and keep them properly Note ensure that the body is placed in a dry place and keep all machine components properly 1 Information on servicing 1 Checks to the area Prior to beginning work on systems containing flammable refri...

Page 13: ...The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere 8 Checks to the refrigeration equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s tech...

Page 14: ...3 Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall be at the correct rati...

Page 15: ...l no refrigerant is within the system When the final OFN charge is used the system shall be vented down to atmospheric pressure to enable work to take place This operation is absolutely vital if brazing operations on the pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available 8 Charging procedures In addition to...

Page 16: ...rant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge is available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve a...

Page 17: ...e pipe becomes dry so as to keep the inside of the body in a dry state and prevent it from mildewing 3 Turn off the machine unplug the power plug and wrap the power cord around the wrapping post install the water plug and the drainage cover 4 Remove the exhaust pipe and keep it properly 5 Cover the air conditioning with a plastic bag Put the air conditioning in a dry place keep it out of the reach...

Page 18: ...re other sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Big Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise compressor does not work Overheat protection starts Wait for 3 minutes until ...

Page 19: ...age 19 20 19 X Addendum Schematic diagram for air conditioning The specific technical parameters of the machine shall be subject to the nameplate on the product Condenser Compressor Evaporator Capillary ...

Page 20: ... are separate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product complies with the requirements of below directives EMC Directive 14 30 EU Low Voltage Directive 14 35 EU ErP Directive 09 125 EC CE Marking 93 68 EEC RoHS Directive 11 65 EU The detailed ...

Reviews: