- 4 -
G
G. Lag in deactivation with support function enabled.
The
leading edge of the START signal results in relay activation,
whereas the trailing edge of the same signal triggers the time
countdown. The supply of the START signal during countdown
results in an extension of the cycle by another "t" time value
along the trailing edge.
H
H. Deactivation and activation lags with support function ena-
bled.
If the START voltage is supplied for less than 45 sec, it is
ignored by the system, however if it is longer, the relay is activa-
ted after the 45 sec and the preset time value is counted down
with the trailing edge of the START signal. If another START im-
pulse is applied during the countdown, then the trailing edge of
this signal will result in the repeated countdown sequence (e.g.
for ventilation purposes: short activation of the lighting does not
turn the fan on, but if the lilting lighting is activated for longer
than the 45 sec, the fan will start.