background image

- 4 -

G

G. Lag in deactivation with support function enabled. 

The 

leading edge of the START signal results in relay activation, 

whereas the trailing edge of the same signal triggers the time 

countdown. The supply of the START signal during countdown 

results in an extension of the cycle by another "t" time value 

along the trailing edge.

H

H. Deactivation and activation lags with support function ena-

bled. 

If the START voltage is supplied for less than 45 sec, it is 

ignored by the system, however if it is longer, the relay is activa-

ted after the 45 sec and the preset time value is counted down 

with the trailing edge of the START signal. If another START im-

pulse is applied during the countdown, then the trailing edge of 

this signal will result in the repeated countdown sequence (e.g. 

for ventilation purposes: short activation of the lighting does not 

turn the fan on, but if the lilting lighting is activated for longer 

than the 45 sec, the fan will start.

Summary of Contents for PCS-506

Page 1: ...elay off The device does not respond to time range settings Purpose Operating F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl Donotdisposeofthisdeviceinthetrashalongwithotherwaste According to the Law on Waste electro coming from households free of charge and can give any amount to up to that end poi...

Page 2: ...elay Two START impulses applied within a time shorter than 1 sec will result in the permanent activation of the relay The following impulse turns the relay OFF C C Generator with a pulse duty factor of 50 which initiates it s working sequence from the moment of activation It is active as long as START voltage is applied Once the START signal is discon nected the connection is broken and the device...

Page 3: ...railing edge of the reset signal and the leading edge of the START signal which re initiates the countdown sequence should be at least 0 5 sec E E Generation of a single impulse of t time by the START si gnal up trailing edge During preset time countdown the system does not respond to START impulses F F Generation of a single impulse of t time by the START signal down trailing edge During preset t...

Page 4: ...upport function ena bled If the START voltage is supplied for less than 45 sec it is ignored by the system however if it is longer the relay is activa ted after the 45 sec and the preset time value is counted down with the trailing edge of the START signal If another START im pulse is applied during the countdown then the trailing edge of this signal will result in the repeated countdown sequence ...

Page 5: ... t for example 1 m 7 7 min The black box in the diagram shows the position of the switch 5 4 6 OFF 5 0 1 s 4 6 1 s 5 4 6 10 s 5 4 6 1 min 5 4 6 ON 5 4 6 2 h 5 4 6 10 min 5 4 6 Time ranges The required time range and the working mode of the relay is selected by choosing the proper combination of the switches black field in the diagram stands for the switch position A E 3 B F C G D H 2 1 3 2 1 3 2 1...

Page 6: ...r the power supply is switched off and back on With the power supply on it is possible to regulate the preset time freely within the selected time range 0 1s 0 1 1 2sec 10m 10 120min 1s 1 12sec 2h 2 24 h 10s 10 120sec 1d 1 12days 24 288h 1m 1 12min 2d 2 24days 48 576h ON position with power supply activated causes the contact to be permanently opened OFF position with power supply activated causes...

Page 7: ...e one of control impulse option L or N Control buttons connected in parallel connect between the red wire and the wire of the selected control signal option L or N 5 Connect the controlled receiver to the black wire and the neu tral wire N 6 By code switches set work function and time range 7 By knob set time work Mounting Wiring diagram ...

Page 8: ... covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration of Conformity along with the referen...