background image

- 4 -

Press the selected button on a remote control or in 

a flush-mounted transmitter.

Correct pairing will be confirmed by temporary switching off of the output 

circuit and the LED will turn on again.

Each channel of the receiver can be paired with eight different transmitters 

(remote buttons). Pairing with more buttons will remove the first entries 

made.

Unpairing

To clear the list of transmitters cooperating with the receiver, press the PROG button and hold it 

down for at least 10 seconds. Fast flashing of communication LED will indicate that the memory 

of the controller has been cleared.

Local buttons

Short press of a button switches the relay in to the opposite state.

Long press of a button (longer than 5 second) activates the relay regardless of the state, in which 

the relay was previously in. This feature can be used for synchronizing a group of receivers con-

nected to the same local button. Releasing the button sets the relay in the on position.

Remote buttons

The FW-RC4, FW-RC10 transmitters operate on the principle of a bistable switch: one 

press of a button activates the relay; the second press of button deactivates the relay. 

The FW-RC5 transmitter also has separate inputs ON (always ON) and OFF (always 

OFF).

Due to the nature of transmission and retransmission do not use the same 

button in transmitter more often than every 2 seconds. Switching of the re-

ceiver may be carried out with a short delay.

Summary of Contents for FW-R2D

Page 1: ... threat to the environment and human health 1 Description of the system F Wave is a family of wireless devices controlled by radio with a range of up to 100 meters The receivers are available in either a DIN rail mounting version housing 1S or a ø60 flush mounted version The transmitters are available as handheld remo te controllers or as a flush mounted version The receivers relay control signals...

Page 2: ...ontrol transmitters of the F Wave system The ability to control from up to 8 transmitters 2 local control inputs the ability to directly control the relay using any monostable buttons for example bell buttons 2 independently separated output contact NO with load capacity of 16 A AC 1 Compact enclosure takes only one field in the switchboard Retransmission of commands from the transmitter the abili...

Page 3: ...capacity 2 16 A 250 V AC 1 The actual maximum load depends on the nature and design of the receiver For more information visit www fif com pl Pairing Each channel of the receiver is independently paired After proper connection press and hold the PROG button until the circuit of the first channel will switch on and the communication LED will go off To select a second channel for pairing hold the pr...

Page 4: ...l buttons Shortpressofabuttonswitchestherelayintotheoppositestate Longpressofabutton longerthan5second activatestherelayregardlessofthestate inwhich therelaywaspreviouslyin Thisfeaturecanbeusedforsynchronizingagroupofreceiverscon nectedtothesamelocalbutton Releasingthebuttonsetstherelayintheonposition Remote buttons The FW RC4 FW RC10 transmitters operate on the principle of a bistable switch one ...

Page 5: ...dbyasteadypulsingofcommunication LED switching off of the output circuit and the lack of its reactivation possibility After lowering the temperature to a safe value the output circuit will remain switched off untilrestarted Devices of the F Wave system Battery transmitters Type Product Flood sensor FW FS1 Remote control FW KEY FW RC4 FW RC10 Wall button FW WS1 FW WS2 FW WS3 FW WSO1 FW WSO2 FW WSO4...

Page 6: ...D Double multifunction relay FW R2P P FW R2P NN FW R2D P Roller blind controller FW STR1P FW STR1D Roller blind multifunction controller FW STR1P P FW STR1D P Technical data power supply 85 265 V AC DC control input 85 265 V AC DC 1 mA power consumption operating mode 1 00 W standby 0 25 W output load capacity AC 1 2 16 A 250 V radio frequency 868 MHz maximum emitted frequency power 10 mW working ...

Page 7: ...he harmonisation of the laws of the Member States relating to the ma king available on the market of radio equipment and repealing Directive 1999 5 EC The CE Declaration of Conformity along with the references to the standards in rela tion to which conformity is declared can be found at www fif com pl on the product page Compliance with the standards PN EN 55024 2011 PN EN 60669 1 2006 PN EN 60669...